Mich. Admin. Code R. 408.15252 - Kilns
Rule 5252.
(1)
A kiln door shall have a device to hold it open during a loading or unloading
cycle. A counterweight for the kiln door shall be guarded as prescribed in
General Industry Safety Standard Part 7 "Guards and Power Transmission," as
referenced in R 408.15209. Installation of a kiln door shall be such that it
will not topple if it becomes disengaged from the carriers or
hangers.
(2) If procedures require
access to a kiln, then either of the following applies:
(a) The kiln shall be provided with an escape
hatch that opens from the inside, swings with the direction of travel, and is
located in or near the main kiln door.
(b) A passageway shall be provided on not
less than 1 side or in the center of an end piled kiln, or on 2 sides of a
cross piled kiln.
(3) A
steam line less than 7 feet from the floor and in or by a walkway shall be
covered with an insulating material or protected by a barrier.
(4) A kiln car shall be blocked by chocks to
prevent unintentional movement.
(5)
A kiln shall be constructed on a foundation capable of preventing the sagging
of the racks.
(6) Where a pit is
provided, it shall be ventilated, drained, and lighted and large enough to give
the operator safe working space with operating devices such as valves, dampers,
damper rods, and traps.
(7) A warm
room shall be provided for kiln employees to stay in during cold weather after
leaving a hot kiln.