Mich. Admin. Code R. 408.16247 - Plastic scrap granulators

Rule 6247.

(1) The opening of a hopper of a plastic scrap granulator shall be of such distance from the cutting knives that the fingers of an employee cannot make contact. A baffle gate shall be installed at the feed entrance of a hopper so that the opening is normally closed except for charging with scrap.
(2) An access opening for maintenance, cleaning or inspection shall be covered with a solid plate, secured by a fastener which requires the use of a tool to unfasten it.
(3) Before a hopper is removed, a plastic scrap granulator shall have the power source disconnected and locked out.

Notes

Mich. Admin. Code R. 408.16247
1979 AC

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.