Mich. Admin. Code R. 408.16546 - Calender stopping limits

Rule 6546. A calender, regardless of size or configuration, shall be stopped by braking equipment within a distance, measured in inches of surface travel of the fastest roll, of not more than 1 3/4% of the peripheral no-load surface speed of the calender rolls as determined in feet per minute. (See figure 3)

**** INSERT MISSING TABLE OR CHART - SEE ORIGINAL MANUSCRIPT ****

All measurements on calenders shall be taken with the rolls running empty at maximum operating speed. Stopping distances shall be expressed in inches of surface travel of the fastest roll from the instant the emergency stopping device is actuated.

Notes

Mich. Admin. Code R. 408.16546
1979 AC

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.