Mich. Admin. Code R. 408.30537d - [Rescinded effective 8/29/2025] Frames of ranges and clothes dryers
Rule 537d.
Section E4101.8 of the code is added to read as follows:
Exception: For existing branch-circuit installations only where an equipment grounding conductor is not present in the outlet or junction box, the frames of electric ranges, wall-mounted ovens, counter-mounted cooking units, clothes dryers, and outlet or junction boxes that are part of the circuit for these appliances may be connected to the grounded circuit conductor if all of the following conditions are met: [250.140 Exception]