Mich. Admin. Code R. 408.41221 - Stilts
Rule 1221.
(1)
A stilt shall be inspected for damage, wear, and corrosion. A defective stilt,
including the pins and straps, shall be repaired or replaced before being
placed in use.
(2) Stilts shall be
used only if all of the following conditions exist:
(a) Floors are level.
(b) All floor holes are securely
covered.
(c) When an employee is
using stilts, the top edge height of the top rail, or equivalent member, shall
be increased an amount equal to the height of the stilts.
(d) The floor is capable of supporting a load
on the stilts base plate without deformation of more than 1/4 of an
inch.
(e) The floor is cleared of
debris, materials, or liquids that could cause a slipping or tripping
hazard.
(3) Stilts shall
not be used while going from one level to another.
(4) An employee may wear stilts on a scaffold
only if it is a large area scaffold.