Mich. Admin. Code R. 408.7037a - Illumination of cars and lighting fixtures
Rule 37a. Section 2.14.7.1.4 of ASME A17.1 is amended to read as follows:
2.14.7.1.4 Each
elevator must be provided with at least 2 electric light fixtures and a ground
fault circuit interrupter duplex receptable on the car top. The 2 light
fixtures combined must provide an illumination level of not less than 10 fc at
any point on the car top. The light fixtures must be permanent and be of the
fixed or portable type and be equipped with guards.