Mich. Admin. Code R. 408.7071 - Location

Rule 71. Section 5.4.8 of the ANSI A10.4 standard is amended to read as follows: 5.4.8.

(1) A personnel hoist must be installed not less than 10 feet from any other lifting or lowering apparatus except other personnel hoists.
(2) A hoistway may not be located either partially or wholly over sidewalks or passageways.
(3) If tower cranes or any other lifting or lowering apparatus are installed such that the boom, load, or trolley may go over or into the 10-foot restricted area, then the personnel hoist must be unoccupied anytime the boom, or trolley passes over the restricted area. The evacuation of the personnel hoist must be the responsibility of the crane operator and the general contractor.