Minn. R. agency 151, ch. 1303, pt. 1303.2320 - WINDOW FALL PREVENTION REQUIRED

Windows that are required to comply with part 1303.2310 must be equipped with window fall prevention screens, guards, or other devices that comply with ASTM F 2006 or ASTM F 2090.

Exceptions:

1. Fixed, nonoperable windows.
2. Windows located in basements.
3. Windows located below the first story above grade plane.
4. Windows in which the opening of a window in any position does not permit a four-inch diameter sphere to pass through the opening.
5. Windows in which the bottom of the sill is more than 24 inches (610 mm) above the finished floor.

Notes

Minn. R. agency 151, ch. 1303, pt. 1303.2320
33 SR 1859

Statutory Authority: MS s 326B.02; 326B.101; 326B.106; 326B.13

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.