Minn. R. 1305.1013 - SECTION 1013, GUARDS
Subpart 1.
IBC section 1013.2.
IBC section 1013.2 is amended by adding an exception as follows:
Exception:
8. In accordance with the Minnesota Bleacher
Safety Act, Minnesota Statutes, . section 326B .112, guards are not required on
bleachers 55 inches or less in height.
Subp. 2.
IBC section 1013.3.
IBC section 1013.3 is amended by modifying exception 4 to read as follows:
4. The guard height in
assembly seating areas shall be in accordance with section 1028.14 and the
Minnesota Bleacher Safety Act, Minnesota Statutes, section
326B.112.
Subp. 3.
IBC section
1013.8.
IBC section 1013.8 is amended to read as follows:
1013.8
Window sills. In
occupancy groups R-1, R-2, and R-3 where the lowest part of the opening of an
operable window is located more than 72 inches (1829 mm) above the finished
grade or. other surface below, the lowest part of the window opening shall be
at a height not less than 36 inches (914 mm) above the finished floor surface
of the room in which the window is located. Operable sections of windows shall
not permit openings that allow passage of a 4-inch-diameter (102 mm) sphere
where such openings are located within 36 inches (914 mm) of the finished
floor.
Exceptions;
1. Operable windows where the lowest part of
the opening is located more than 75 feet (22860 mm) above the finished grade or
other surface below and that are provided with window fall-prevention devices
that comply with ASTM F 2006.
2.
Windows whose openings will not allow a 4-inch-diameter (102 mm) sphere to pass
through the opening when the window is in its largest opened
position.
3. Openings that are
provided with window fall-prevention devices that comply with ASTM F
2090.
4. Windows that are provided
with window opening control devices that comply with section
1013.8.1.
5. Replacement windows
for occupancy groups R-l, R-2, and R-3 located on or below the third story
above grade plane.
1013.8.1
Window opening control devices. Window opening control devices shall
comply with ASTM F 2090. The window opening control device, after operation to
release the control device allowing the window to fully open, shall not reduce
the minimum net clear opening area of the window unit to less than the area
required by section 1029.2.