Minn. R. 1305.2510 - SECTION 2510, LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
IBC section 2510.6 is amended to read as follows:
2510.6
Water-resistive barriers.
Water-resistive barriers shall be installed as required in Section
1403.2 and, where applied over wood-based sheathing, shall include a
water-resistive, vapor-permeable barrier with a performance at least equivalent
to two layers of Grade D paper.
Exception: Where the water-resistive barrier that is applied over wood-based sheathing has a water resistance equal or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially non-water-absorbing layer or drainage space.