Gravity loads. IEBC section 1007.1 is amended to read as follows:
1007.1
Gravity loads. Buildings
or portions thereof subject to a change of occupancy where such change in the
nature of occupancy results in higher uniform or concentrated loads based on
Table 1607.1 of the International Building Code shall comply with the gravity
load provisions of the International Building Code.
Exception: Structural elements whose demand-capacity ratio is not increased by more than 5 percent. Additional loads due to snow retention as a result of a change in roof insulation shall be included in the evaluation.
Notes