chapter 6 is amended by adding a
section and subsections to read as follows:
613.2
Installation location.
Where required, adult changing stations shall be installed in accordance with
the locations specified in Section 613.2.1. Where not required but provided,
adult changing stations shall be installed in accordance with the locations
specified in section 613.2.1 or 613.2.2.
613.2.1
Single-user or family or
assisted-use toilet room. Where adult changing stations are required in
an accessible toilet room with only one water closet and one lavatory, or in a
family or assisted-use toilet room, the room shall provide all of the following
components:
1. A dispenser for soap complying
with Section 308.
2. A hand towel
dispenser or hand dryer complying with Table 603.6.
3. A coat hook located in close proximity to
the changing surface.
4. A waste
receptacle.
5. Signage indicating
"Adult Changing Station" provided at the entrance to the room and complying
with the tactile and visual character requirements in Section 703.2.
6. Signage indicating the weight capacity and
instructions for operation of the changing station within the room.
613.2.2
Room or space other
than a toilet room. Where adult changing stations are provided in a room
or space other than a toilet room and including, but not limited to nurses'
work areas, therapist work areas, or special education classrooms, the adult
changing station shall be located in a compartment or room that includes all of
the following components:
1. Privacy provided
by walls, curtains, or partitions.
2. A turning space complying with Section
304.
3. A lavatory complying with
Section 606 or an alcohol-based hand sanitizer dispenser.
4. Where a lavatory is provided in the
compartment or room, provide a dispenser for soap.
5. Where a lavatory is provided in the
compartment or room, provide a hand towel dispenser or hand dryer complying
with Table 603.6.
6. A waste
receptacle.
613.3
Room clearances. An adult
changing station and its supporting structure when in the operational position
shall not obstruct required clear floor spaces and clearances at accessible
elements, maneuvering clearances at doors or at the wheelchair turning spaces.
Exception: The turning spaces shall be permitted
to include a toe clearance of 9 inches (227 mm) minimum above the floor and
shall extend 6 inches (152 mm) maximum below the table, measured from the
finished edge of the table surface when the provided adult changing station is
in the lowest operational position.
613.4
Changing surface. A
changing surface shall be provided and shall comply with Section 613.4.
613.4.1
Safety and performance.
Adult changing stations shall comply with the following safety and performance
requirements:
1. Protect the user from
falling from the changing surface along the open long sides by means such as
retractable safety rails that comply with section 613.4.5.
2. Support a weight of not less than 400 lbs.
(182 kg) applied to the changing surface.
3. Be anchored in place in accordance with
section 903.6, where the adult changing station is required by section
613.2.1.
4. Provide a changing
surface that is smooth, non-absorbent, and resistant to corrosion.
5. Where electrical components are provided,
they shall comply with the Minnesota Electrical Code.
6. Where operable controls are provided for
adult changing stations required by section 613.2.1, they shall comply with
Section 309.4.
613.4.2
Size. The changing surface shall be 70 inches (1778 mm) minimum in
length and 30 inches (762 mm) minimum in width.
613.4.3
Height adjustability.
The changing surface height shall be adjustable at variable heights from 17
inches (432 mm) minimum to 38 inches (965 mm) maximum above the floor as
measured to the top of the changing surface.
Exceptions:
1. Where the adult changing station is
required, a fixed-height changing surface shall be permitted with the approval
of the administrative authority in locations where the applicant provides
documentation of prior incidents of vandalism. The fixed-height changing
surface shall be mounted with the top 19 inches (483 mm) minimum and 23 inches
(584 mm) maximum above the floor.
2. Where the adult changing station is
provided but not required by IBC Section 1109.2.4.1, a fixed-height changing
surface shall be permitted and shall be mounted with the top of the changing
surface 19 inches (483mm) minimum and 23 inches (584mm) maximum above the
floor.
613.4.4
Clearances. Clearances complying with Sections 613.4.4.1 and
613.4.4.2 shall be provided adjacent to the changing surface, measured when the
surface is in the operational position.
613.4.4.1
Side clearance. A
36-inch (914mm) deep minimum side clearance shall be provided along the open
long side of the changing surface.
Exception: In the raised position, the side rail
shall be permitted to overlap the side clearance.
613.4.4.2
End clearance. A
36-inch (914mm) wide minimum end clearance shall be provided along the depth of
one end of the changing surface. The width of the end clearance shall extend
the depth of the changing surface and the side clearance.
Exceptions:
1. A 24-inch (610mm) wide minimum end
clearance shall be permitted where a clear floor space complying with Section
305.3 is provided within the room beyond the clearances for the changing
surface.
2. Where installed in
locations specified in Section 613.2.2, end clearances complying with Section
613.4.4.2 are not required.
613.4.5
Side rail. Where side
rails are provided at the changing surface they shall comply with Sections
613.4.5.1 and 613.4.5.2.
613.4.5.1
Size
and location. Side rails shall be a minimum of 2/3 of the length of the
changing surface and shall be centered +/- 3 inches (75mm) along the long open
sides of the changing surface.
613.4.5.2
Rail positioning. Side
rails shall be capable of being raised and lowered. The side rail shall be
fixed in place when in the raised position. The top of the side rail shall
extend 5 inches (127mm) minimum above the top of the changing
surface.