Minn. R. agency 167, ch. 7011, HOT MIX ASPHALT PLANTS, pt. 7011.0911 - MAINTENANCE OF DRYER BURNER
Subpart 1.
Annual tuning of dryer burner.
The owner or operator of a hot mix asphalt plant must tune the dryer burner for maximum combustion efficiency once each calendar year.
Subp. 2.
Daily check of dryer burner.
The owner or operator of a hot mix asphalt plant must do the following while producing hot mix asphalt each day except when burning natural gas or propane:
A. read the fuel pressure gauge on the dryer burner; and
B. check for a negative draft at the dryer burner inlet.
Subp. 3.
Records kept on dryer burner.
The owner or operator of a hot mix asphalt plant must maintain a record of:
A. the dates of the annual tuning of the dryer burner;
B. the daily reading from the fuel pressure gauge on the dryer burner except when burning natural gas or propane;
C. whether there was a negative draft at the dryer burner inlet each day except when burning natural gas or propane; and
D. any corrective actions taken as a result of the daily checks required by subpart 2.
Notes
Statutory Authority: MS s 116.07
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.