Minn. R. agency 167, ch. 7080, pt. 7080.2280 - PRIVIES

A. To qualify as a privy, the system must:
(1) meet or exceed the requirements of part 7080.2150, subpart 2;
(2) have soil beneath the bottom of the pit that meets or exceeds the requirements of part 7080.2150, subpart 3, item C, employ a watertight tank meeting applicable requirements of parts 7080.1900 to 7080.2030, or employ a toilet treatment device; and
(3) meet the requirements of items B to E.
B. Pits or vaults must have sufficient capacity for the dwelling they serve, but must have at least 25 cubic feet of capacity.
C. The sides of the pit must be curbed to prevent cave-in.
D. The privy must be easily maintained and insect proof. The door and seat must be self-closing. All exterior openings, including vent openings, shall be screened.
E. Privies must be adequately vented.

Notes

Minn. R. agency 167, ch. 7080, pt. 7080.2280
32 SR 1347

Statutory Authority: MS s 115.03; 115.55

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.