11 Miss. Code. R. § 8-2.5-53-5347 - Use of Explosives: General Requirements
(a) Each
operator shall comply with all applicable state and federal laws and
regulations in the use of explosives.
(b) Blasts that use more than five pounds of
explosive or blasting agent shall be conducted according to the schedule
required under § 5351.
(c) Blasters
(1) All blasting operations in the state
shall be conducted under the direction of a certified blaster and in accordance
with Policy Statement No. PS-1 entitled "Blasters Certification Requirements,
Surface Coal Mining and Reclamation Operations". All such blasting operations
in the state shall be conducted by competent, experienced persons who
understand the hazards involved.
(2) Certificates of blaster certification
shall be carried by blasters or shall be on file at the permit area during
blasting operations.
(3) A blaster
and at least one other person shall be present at the firing of a
blast.
(4) Any blaster who is
responsible for conducting blasting operations at a blasting site shall:
(A) be familiar with the blasting plan and
site-specific performance standards; and
(B) give direction and on-the-job training to
persons who are not certified and who are assigned to the blasting crew or
assist in the use of explosives.
(d) Blast Design
(1) An anticipated blast design shall be
submitted if blasting operations will be conducted within:
(A) 1,000 feet of any building used as a
dwelling, public building, school, church, community or institutional building
outside the permit area; or
(B) 500
feet of an active or abandoned underground mine.
(2) The blast design may be presented as part
of a permit application or at a time, before the blast, approved by the
Department.
(3) The blast design
shall contain sketches of the drill patterns, delay periods and decking and
shall indicate the type and amount of explosives to be used, critical
dimensions, and the location and general description of structures to be
protected, as well as a discussion of design factors to be used, which protect
the public and meet the applicable airblast, flyrock and ground-vibration
standards in § 5355.
(4) The blast
design shall be prepared and signed by a certified blaster.
(5) The Department may require changes to the
design submitted.
(6) No blasting
shall occur until the blast design is approved in writing by the Department. No
blast design shall be approved by the Department unless it fulfills the
requirements of §
53-9-25
and the blast plan is previously approved by the Permit Board.