15 Miss. Code. R. 11-55-2.11.3 - Openings
1. Each window, exterior door, and basement
or cellar hatchway shall be weather tight and watertight.
2. All windows above ground level in areas
used by children under five years of age shall be constructed, adapted, or
adjusted to limit the exit opening accessible to children to less than six
inches, or be otherwise protected with guards that do not block outdoor
light.
3. Openable windows shall be
of a safety type (not fully openable) that are child proofed and screened when
open. When there are no openable windows, or when windows are not kept open,
rooms shall be adequately ventilated.
4. All openings used for ventilation shall be
screened.
5. The width of doors
shall accommodate wheelchairs and the needs of individuals with physical
disabilities.
6. Exit doors shall
open outward. Boiler room doors shall swing inward.
7. Doorways and exits shall be free of debris
and equipment to allow unobstructed traffic to and from the room.
8. The hand contact and splash areas of doors
and walls shall be covered with an easily cleanable finish, at least as
cleanable as an epoxy finish or enamel paint.