15 Miss. Code. R. 18-77-6.1.4 - Location/Setbacks
1. The disinfection system shall not be
located in an area that collects surface water.
2. The disinfection system shall be installed
according to the following setbacks:
a. 5
feet from foundations, deck, out-building, etc
b. 10 feet from property lines
c. 50 feet from any public, private or
individual potable water source
3. No vehicular traffic shall be allowed over
the tank(s), disinfection system or any part of the Individual On-site
Wastewater disposal System.
4.
Tanks and disinfection system shall not be located under dwellings or other
permanent structures.