19 Miss. Code. R. 7-5.06.10.2 - Multi-sectional Factory-Built Homes

A. All used multi-sectional Factory-Built homes shall have diagonal ties and anchors as required above for single-wide Factory-Built homes as listed in Tables VI and VII above. The number of anchors and straps along the mate line of the multi-sectional Factory-Built home shall be one/half of the required number for one side of a single wide unit having the same length. A minimum of two of the anchor and straps are to be placed within 2 ft. of the end of each section of the home.
B. The installation of anchors and diagonal ties will be required along the mate line on all used multiple section Factory-Built homes unless the manufacturers installation manual for the home is available and specifies that these stabilizing devices are optional.
C. All new multi- sectional Factory-Built homes are to be secured at the centerline with straps and anchors to the specifications in the manufacturer's installation manual or at the locations designated on the home. In addition to centerline ties specified by the manufacturer, a centerline tie must be attached within two (2) feet of each end of each section of the Factory-Built home. Where necessary, an approved bracket shall be installed by the installer/transporter.
D. All multi-sectional homes shall be lagged and sealed together in accordance with the manufacturer's installation instructions. If no manufacturer's installation instructions are available, the instructions provided in this regulation shall be followed.

Notes

19 Miss. Code. R. 7-5.06.10.2
Miss. Code Ann. ยงยง 75-49-1, et seq.; 75-49-11 (Supp. 2015).
Adopted 1/1/2015 Amended 10/1/2016