30 Miss. Code. R. 2101-8.9 - Disinfecting Work Surfaces, Instruments, Materials and Supplies
A. Work surfaces must be cleaned with a
detergent and disinfected after each client.
B. All instruments, materials and supplies
used in direct contact upon a patron, except those which come in contact with
blood or body fluids, require the following treatment:
1. Thorough cleansing of the instruments,
materials and supplies with soap and water or other detergent immediately after
each use, and prior to disinfection, so as to remove all foreign material which
might harbor bacteria.
2. Each
establishment will have and use for disinfection at all times during business
hours, a Wet Disinfectant Container made of glass, stainless steel, or the type
recommended by the manufacturer of the product it contains.
a. The disinfectant used must be an EPA
registered, hospital grade, bactericidal, virucidal and fungicidal
disinfectant.
b. The solution will
be mixed and used according to manufacturer's instructions for dilution and
immersion time.
c. The container
will be large enough for total immersion of the open implement and will contain
the appropriate amount of solution for the number of items to be
disinfected.
d. The container will
have a cover in place at all times, labeled as to its contents, and be easily
accessible to all practitioners.
e.
Implements are to be removed from the disinfectant in such a manner as not to
contaminate the disinfectant solution (using tongs, baskets, and such), and
placed on a clean dry towel for air drying.
f. Ultraviolet ray cabinets may be used, but
are not acceptable as approved disinfecting devises. Glass bead sterilizers are
not an acceptable disinfectant.
3. Storage of Disinfected Implements:
Disinfected combs, brushes, instruments and accessories will be kept in a clean, sanitized, closed receptacle or cabinet when not in use.
C. Body
treatment, pedicure and manicure equipment that holds water shall be cleaned
after each client by scrubbing with surfactant soap and water
to remove all visible residue, then disinfected with an EPA registered
bactericide, fungicide, and virucidal disinfectant with surface contact
according to manufacturer's directions
D. All tools and implements which have come
in contact with blood or body fluids must be disinfected in the manner
stipulated in Rule 8.9.B., except that the disinfectant must be an EPA
registered, hospital grade, tuberculocidal that is mixed and
used according to the manufacturer's direction. Disposable items must be
discarded immediately, following the Blood Spill Procedures as stipulated in
Rule 8.13.