Mont. Admin. r. 37.14.846 - PRECAUTIONARY PROCEDURES IN RADIOGRAPHIC OPERATIONS: SPECIAL REQUIREMENTS AND EXEMPTIONS FOR ENCLOSED RADIOGRAPHY
(1)
Systems for enclosed radiography designed to allow admittance of individuals
shall:
(a) Comply with all applicable
requirements of this subchapter and ARM
37.14.710. If such a system is a
certified cabinet x-ray system, it shall comply with all applicable
requirements of this subchapter and
21 CFR
1020.40.
(b) Be evaluated at intervals not to exceed 1
year to assure compliance with the applicable requirements as specified in (a)
above.
(i) Records of these evaluations shall
be maintained for inspection by the department for a period of 2 years after
the evaluation.
(2) Cabinet x-ray systems designed to exclude
individuals are exempt from the requirements of this subchapter except that:
(a) Operating personnel must be provided with
either a film badge or a thermoluminescent dosimeter and reports of the results
must be maintained for inspection by the department.
(b) No registrant shall permit any individual
to operate a cabinet x-ray system until such individual has received a copy of
and instruction in the operating procedures for the unit and has demonstrated
competence in its use. Records which demonstrate compliance with this
subsection shall be maintained for inspection by the department until
disposition is authorized by the department.
(c) Tests for proper operation of high
radiation area control devices or alarm systems, where applicable, must be
conducted and recorded in accordance with ARM
37.14.823.
(d) The registrant shall perform an
evaluation at intervals not to exceed 1 year, to determine conformance with ARM
37.14.710. If such a system is a certified cabinet x-ray system, it shall be
evaluated at intervals not to exceed 1 year to determine conformance with
21 CFR
1020.40.
(i) Records of these evaluations shall be
maintained for inspection by the department for a period of 2 years after the
evaluation.
(3) Certified cabinet x-ray systems shall be
maintained in compliance with
21 CFR
1020.40 unless prior approval has been
granted by the department pursuant to ARM
37.14.106.
APPENDIX A
Subjects to be covered during the instruction of radiographers
I.
Fundamentals of Radiation Safety
A. Characteristics of radiation
B. Units of radiation dose (mrem) and
quantity of radioactivity (curie)
C. Significance of radiation dose
1. Radiation protection standards
2. iological effects of radiation
dose
D. Levels of
radiation from sources of radiation
E. Methods of controlling radiation dose
1. Working time
2. Working distances
3. Shielding
II.
Radiation Detection
Instrumentation to be Used
A.
Use of radiation survey instruments
1.
Operation
2. Calibration
3. Limitations
B. Survey techniques
C. Use of personnel monitoring equipment
1. Film badges
2. Thermoluminescent dosimeters
3. Pocket dosimeters
III.
Radiographic
Equipment to be Used
A. Remote
handling equipment
B. Radiographic
exposure devices and sealed sources
C. Storage containers
D. Operation and control of x-ray
equipment
IV.
The Requirements of Pertinent Federal and State Regulations
V.
The
Licensee's or Registrant's Written Operating and Emergency Procedures
Notes
Sec. 75-3-201 and 75-3-202, MCA; IMP, Sec. 75-3-201 and 75-3-204, MCA;
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.