Nev. Admin. Code § 445B.22096 - Control measures constituting BART; limitations on emissions
|
UNIT (Boiler) |
NOx |
SO2 |
PM10 |
|||
|
Emission Limit (lb/106 Btu, 12-month rolling average) |
Control Type |
Emission Limit (lb/106 Btu, 24-hr average) |
Control Type |
Emission Limit (lb/106 Btu, 3-hr average) |
Control Type |
|
|
1 |
0.20 |
Low NOx burners with flue gas recirculation |
0.05 |
Pipeline natural gas and/or No. 2 fuel oil |
0.03 |
Pipeline natural gas and/or No. 2 fuel oil |
|
2 |
0.16 |
0.05 |
0.03 |
|||
|
UNIT (Boiler) |
NOx |
SO2 |
PM10 |
|||
|
Emission Limit (lb/106 Btu, 12-month rolling average) |
Control Type |
Emission Limit (lb/106 Btu, 24-hr average) |
Control Type |
Emission Limit (lb/106 Btu, 3-hr average) |
Control Type |
|
|
1 |
0.15 |
Low NOx burners with flue gas recirculation |
0.05 |
Pipeline natural gas and/or No. 2 fuel oil |
0.03 |
Pipeline natural gas and/or No. 2 fuel oil |
|
2 |
0.12 |
0.05 |
0.03 |
|||
|
3 |
0.19 |
Low NOx burners with selective noncatalytic reduction |
0.05 |
0.03 |
||
Notes