N.H. Admin. Code § Lab 1403.16 - Disposal Chutes
The employer shall ensure compliance with the following requirements:
(a) Whenever materials
are dropped more than 20 feet to any exterior point of a building, an enclosed
chute shall be used; and
(b) When
debris is dropped through holes in the floor without the use of chutes, the
area where the material is dropped shall be enclosed with barricades not less
than 42 inches high and not less than 6 feet back from the projected edges of
the opening above. Warning signs of the hazard of falling material shall be
posted at each level.
Notes
#4118 eff 8-22-86, EXPIRED: 8-22-92
New. #6684, eff 2-4-98, EXPIRED: 2-4-06
New. #8606, INTERIM, eff 4-12-06, EXPIRED: 10-09-06 (formerly Lab 1403.18)
New. #8796, eff 1-11-07
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.