N.M. Admin. Code § 14.7.2.31 - CHAPTER 23 - WOOD
See this chapter of the IBC except as provided below. Section 2308 - Conventional Light-Frame Construction. See this section of the IBC except as provided below.
A.
Section 2308.4.5 - Joists supporting
bearing partitions. See this section of the IBC except delete the first
sentence and substitute: bearing partitions parallel to joists shall be
supported on beams, girders, built-up joists of sufficient size to carry the
load, walls, or other bearing partitions.
B.
Section 2308.7.6 - Framing around
openings. See this section of the IBC except delete the first sentence
and substitute: Trimmer and header joists shall be of sufficient size to
support the load.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.