N.M. Admin. Code § 14.7.5.11 - WALL REINFORCING
A. The
bottom course of the bale wall shall be pinned to the foundation with #4 rebar
with a minimum of two pins per bale. These pins should be embedded into the
foundation to a depth of not less than seven inches (7") and should continue
vertically halfway into the second course of bales.
B. Each subsequent course of bales shall have
two (2) rebar pins per bale that extend vertically through that course and
halfway into the second adjacent course below penetrating a total of two and
one half courses. All rebar shall be located approximately nine inches (9")
from the bale ends and centered on the width of the bale.
C. A continuous horizontal ladder reinforcing
shall be placed horizontally between courses at mid wall height and shall be
fastened twice per bale to the twine or wire.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.