N.M. Admin. Code § 8.370.19.42 - CARPETING

Carpets may be used in patient and non-patient occupied areas with the following exceptions: toilet rooms, bathing facilities, isolation rooms, laundry rooms, utility rooms, examination or treatment rooms, housekeeping closets:

A. Specifications for acceptable carpeting include:
(1) carpet material which meets the standards of the state fire marshal and is easily cleanable;
(2) pile tufts shall be a minimum of 64 per square inch or equivalent density;
(3) rows shall be a minimum of eight per square inch or equivalent density.
B. Installation of carpet material:
(1) Pad and carpet shall be installed according to manufacturer recommendations;
(2) Edges of carpet shall be covered and cove or base shoe used at all wall junctures. Seams shall be sewn or bonded together with manufacturer recommended cement.

Notes

N.M. Admin. Code § 8.370.19.42
Adopted by New Mexico Register, Volume XXXV, Issue 12, June 25, 2024, eff. 7/1/2024