N.M. Admin. Code § 8.371.2.50 - DOORS
A. All client
sleeping room doors must be at least one and three quarter inches bonded solid
core with a minimum width of 30 inches.
B. All exit doors must have a minimum width
of 36 inches.
C. All doors to
toilet and bathing facilities must have a minimum width of 24 inches.
D. Locks on doors to toilets, if used, shall
be of such type that the lock can be released from the outside.
E. Exit doors leading to the outside of the
facility with a capacity of 10 or more clients must open outward. Exit doors
may be provided with a night latch, dead bolt, or security chain, provided such
devices are openable from the inside without the use of a key, tool, or any
special knowledge and are mounted at a height not to exceed 48 inches above the
finished floor.
F. If locks are not
readily openable by all occupants within the building, then the locks must:
(1) unlock upon activation of the fire
detection or sprinkler system;
(2)
unlock upon loss of power in the facility. The facility must have written
approval from the fire authorities having jurisdiction prior to installing such
locking devices.