(A) Exhaust emissions for diesel-powered
equipment shall
is
to be monitored and controlled using the control and conditioning systems
of rule
1501:10-2-05 of the
Administrative Code, the threshold limits and other requirements
provisions of rule
1501:10-2-07 of the
Administrative Code, the baseline exhaust emissions values established in rule
1501:10-2-20 of the
Administrative Code, and the diagnostic testing of this rule.
(B) Equipment maintenance diagnostic testing.
At intervals not to exceed one hundred hours of engine operation, a mechanic
qualified in accordance with rule
1501:10-2-24 of the
Administrative Code shall
is to perform equipment maintenance diagnostic testing
of each piece of diesel-powered equipment in the mine and make all necessary
adjustments and repairs to meet the manufacturer's specifications and
the requirements of this chapter, or remove
the equipment from service. The qualified mechanic shall
is to:
(1) Verify the identification numbers on the
equipment;
(2) Check the level of
the engine lubricating oil;
(3)
Check the level of the transmission fluid;
(4) Set the brakes and chock the
wheels;
(5) Install a functioning
portable carbon monoxide (CO) sampling device into the untreated exhaust port
coupling provided in the operator's cab;
(6) Start the engine and allow it to attain
normal operating temperature;
(7)
At high idle speed, check the intake restriction and the exhaust back
pressure;
(8) If the intake
restriction is more than the manufacturer's maximum specified intake
restriction, replace the intake filter with a new one;
(9) If exhaust gas backpressure is above that
specified by the manufacturer, take steps to bring the exhaust gas backpressure
back within the manufacturer's specified limit prior to again beginning the
equipment maintenance diagnostic testing of paragraph (B) of this
rule;
(10) For mobile equipment,
shift into the highest gear and fully accelerate the engine, or for stationary
equipment, induce a load and put the engine at full throttle. Maintain full
acceleration or full throttle for a minimum of sixty seconds prior to taking
the reading required under
set forth in paragraph (B)(11) of this rule to
dissipate any reading inaccuracies due to turbo lag;
(11) Start the portable CO sampling device,
record the CO level after sixty seconds, after seventy-five seconds, and after
ninety seconds, and then take the average of these three readings;
(12) Install the portable CO sampling device
into the treated exhaust port coupling provided in the operator's cab and
repeat steps of paragraphs (B)(10) and (B) (11) of this rule; and
(13)
Comply with
record keeping requirements of
Keep records in
compliance with rule
1501:10-2-17 of the
Administrative Code.
(C)
For any diesel-powered equipment tested under paragraph (B) of this rule, if
the average CO reading for untreated exhaust emissions is greater than twice
the baseline established under paragraph (B) of rule
1501:10-2-20 of the
Administrative Code, or if the average CO reading for treated exhaust gas is
greater than one hundred parts per million (ppm), the equipment has failed the
diagnostic test. A mechanic qualified in accordance with rule
1501:10-2-24 of the
Administrative Code shall
is to service and retest the equipment until it meets
the standards of this chapter before the equipment is returned to regular
service.
(D) The chief may approve
an alternative to the equipment maintenance diagnostic testing procedure of
paragraph (B) of this rule.