Ohio Admin. Code 1501:21-13-06 - Requirements for drains and other pipe conduits
(A) Unless specifically exempted by the
chief, dams in class I, class II, and class III shall include a device to
permit draining the reservoir within a reasonable period of time as approved by
the chief. Pipe conduits used for lake drains shall have a minimum inside
diameter of not less than four inches and must be placed at an elevation to account for
sedimentation in the reservoir.
(B)
Valves or sluice gates in pipe conduits shall be installed upstream from the
centerline of the dam unless otherwise approved by the chief.
(C) All pipe conduits used as drains, water
supply lines, or other pressure-flow conduits, regardless of classification of
the dam, shall meet the legal provisions
requirements of paragraphs (A), (B), (C),
and (E) of rule
1501:21-13-04 of the
Administrative Code and paragraphs (A), (C), and (D) of rule
1501:21-13-05 of the
Administrative Code.
(D) When the
drain outlets into a pipe-conduit upstream from the centerline of the dam,
seepage control devices may be omitted from the drain.
(E) All new dam construction shall include a
bulkhead for the outlet works unless specifically exempted by the
chief.