Ohio Admin. Code 3701:1-52-11 - Radiation monitors
(A) Irradiators with automatic product
conveyor systems must have a radiation monitor with an audible alarm located to
detect loose radioactive sources that are carried toward the product exit. If
the monitor detects a source, an alarm must sound and product conveyors must
stop automatically. The alarm must be capable of alerting an individual in the
facility who is prepared to summon assistance. Underwater irradiators in which
the product moves within an enclosed stationary tube are exempt from the
requirements of this paragraph.
(B) Underwater irradiators that are not in a
shielded radiation room must have a radiation monitor over the pool to detect
abnormal radiation levels. The monitor must have an audible alarm and a visible
indicator at entrances to the personnel access barrier around the pool. The
audible alarm may have a manual shut-off. The alarm must be capable of alerting
an individual who is prepared to respond promptly.