Ohio Admin. Code 3701:1-52-12 - Control of source movement
(A) The mechanism that moves the sources of a
panoramic irradiator must require a key to actuate. Actuation of the mechanism
must cause an audible signal to indicate that the sources are leaving the
shielded position. Only one key may be in use at any time, and only operators
or facility management may possess it. The key must be attached to a portable
radiation survey meter by a chain or cable. The lock for source control must be
designed so that the key may not be removed if the sources are in an unshielded
position. The door to the radiation room must require the same key.
(B) The console of a panoramic irradiator
must have a source position indicator that indicates when the sources are in
the fully shielded position, when they are in transit, and when the sources are
exposed.
(C) The control console
of a panoramic irradiator must have a control that promptly returns the sources
to the shielded position.
(D) Each
control for a panoramic irradiator must be clearly marked as to its function.