Ohio Admin. Code 3701:1-52-21 - Radiation surveys
(A) A radiation survey of the area outside
the shielding of the radiation room of a panoramic irradiator must be conducted
with the sources in the exposed position before the facility starts to operate.
A radiation survey of the area above the pool for pool irradiators must be
conducted after the sources are loaded but before the facility starts to
operate. Additional radiation surveys of the shielding must be performed at
intervals not to exceed three years and before resuming operation after
addition of new sources or any modification to the radiation room shielding or
structure that might increase dose rates.
(B) If the radiation levels specified in rule
3701:1-52-09 of the
Administrative Code are exceeded, the facility must be modified to comply with
the requirements in rule
3701:1-52-09 of the
Administrative Code.
(C) Portable
radiation survey meters must be calibrated at least annually to an accuracy of
plus or minus twenty per cent for the gamma energy of the sources in use. The
calibration must be done at two points on each scale or, for digital
instruments, at one point per decade over the range that will be used. Portable
radiation survey meters must be of a type that does not saturate and read zero
at high radiation dose rates.
(D)
Water from the irradiator pool, other potentially contaminated liquids, and
sediments from pool vacuuming must be monitored for radioactive contamination
before release to unrestricted areas. Radioactive concentrations must not
exceed those specified in accordance with rule
3701:1-38-12 of the Administrative Code, table II, or table III of appendix
C
table II or table III of appendix C to rule
3701:1-38-12 of the
Administrative Code, "Annual Limits on Intake (ALI) and Derived Air
Concentrations (DAC) of Radionuclides for Occupational Exposure; Effluent
Concentrations; Concentrations for Release to Sanitary Sewerage".
(E) Before releasing resins for unrestricted
use, they must be monitored before release in an area with a background level
less than 0.5 microsievert ( 0.05 millirem) per hour. The resins may be
released only if the survey does not detect radiation levels above background
radiation levels. The survey meter used must be capable of detecting radiation
levels of 0.5 microsievert ( 0.05 millirem) per hour.
Notes
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002, 01/15/2017
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002