Ohio Admin. Code 3717-1-04.3 - Equipment, utensils, and linens: location and installation
(A) Equipment,
clothes washers and dryers, and storage cabinets - contamination prevention by
properly locating.
(1) Equipment, a cabinet
used for the storage of food, or a cabinet that is used to store cleaned and
sanitized equipment, utensils, laundered linens, single-service articles, or
single-use articles are not to be located:
(a)
In toilet rooms;
(b) In garbage
rooms;
(c) In mechanical
rooms;
(d) Under sewer lines that
are not shielded to intercept potential drips;
(e) Under leaking water lines including
leaking automatic fire sprinkler heads or under lines on which water has
condensed;
(f) Under open
stairwells;
(g) In locker rooms
unless it is a storage cabinet used only for linens, single- service articles,
or single-use articles; or
(h)
Under other sources of contamination.
(2) If a mechanical clothes washer or dryer
is provided, it is to be located so that the washer or dryer is protected from
contamination and located where there is no exposed food; clean equipment,
utensils, or linens; or unwrapped single- service or single-use
articles.
(B) Fixed
equipment installation - spacing or sealing.
(1) Equipment that is fixed because it is not
easily movable is to be installed so that it is:
(a) Spaced to allow access for cleaning along
the sides, behind, and above the equipment;
(b) Spaced from adjoining equipment, walls,
and ceilings a distance of not more than one thirty-second inch or one
millimeter; or
(c) Sealed to
adjoining equipment or walls, if the equipment is exposed to spillage or
seepage.
(2)
Counter-mounted equipment that is not easily movable is to be installed to
allow cleaning of the equipment and areas underneath and around the equipment
by being:
(a) Sealed; or
(b) Elevated on legs as specified under
paragraph (C)(2) of this rule.
(C) Fixed equipment installation:
- elevation or
sealing.
(1) Floor-mounted equipment that is
not easily movable is to be sealed to the floor or elevated on legs that
provide at least a six inch (fifteen centimeter) clearance between the floor
and the equipment. This paragraph does not apply:
(a) If no part of the floor under the
floor-mounted equipment is more than six inches (fifteen centimeters) from the
point of cleaning access, the clearance space may be only four inches (ten
centimeters).
(b) To display
shelving units, display refrigeration units, and display freezer units located
in the consumer shopping areas of a food service operation or retail food
establishment, if the floor under the units is maintained clean.
(2) Counter-mounted equipment that
is not easily movable is to be elevated on legs that provide at least a four
inch (ten centimeter) clearance between the counter and the equipment, unless
the horizontal distance of the counter top under the equipment from the point
of access for cleaning is no more than:
(a)
Twenty inches (fifty centimeters) and the clearance space is at least three
inches (7.5 centimeters); or
(b)
Three inches (7.5 centimeters) and the clearance space is at least two inches
(five centimeters).
Notes
Promulgated Under: 119.03
Statutory Authority: 3717.04, 3717.05
Rule Amplifies: 3717.04, 3717.05
Prior Effective Dates: 03/01/2001, 03/01/2009, 06/19/2023