[Comment: For dates of non-regulatory government publications,
publications of recognized organizations and associations, federal rules, and
federal statutory provisions referenced in this rule, see paragraph (C) of rule
3745-20-01
of the Administrative Code titled "Referenced materials."]
(A) All asbestos-containing waste material
shall be deposited as soon as is practical by the waste generator at
one of the following :
(1) A waste disposal site in Ohio operated in
accordance with the provisions of rule
3745-20-06
of the Administrative Code
, or
.
(2) A
waste disposal site not in Ohio operated in accordance with the provisions of
40 CFR
61.154
,
or
.
(3) A site that converts regulated
asbestos-containing material and asbestos- containing waste material into
nonasbestos (asbestos-free) material in accordance with the provisions of rule
3745-20-13
of the Administrative Code.
(4) The
requirements of paragraph (A) of this rule do not apply to category I
nonfriable ACM that is not RACM.
(B) Each owner or operator of any demolition,
renovation, manufacturing, fabricating or spraying operation to whom this rule
applies, shall discharge no visible emissions to the outside air during the
collection, processing (including incineration), packaging, transporting, or
deposition of any asbestos-containing waste material, and use one of the
methods specified in paragraphs (B)(1) to (B)(4) of this rule:
(1) Adequately wet asbestos-containing waste
material
as follows
by doing all of the following :
(a) Mix control device asbestos waste to form
a slurry; adequately wet other asbestos-containing waste material
; and
.
(b) Discharge no visible emissions to the
outside air from collecting, mixing, wetting, and handling operations, or use
the methods specified by rule
3745-20-12 of the
Administrative Code to clean emissions containing particulate asbestos material
before they escape to, or are vented to, the outside air
; and
.
(c) After wetting, seal all
asbestos-containing waste material while wet in durable leak-tight containers
or wrapping that complies with paragraph (C) of this rule.
(2) For facilities demolished in accordance
with paragraph (A)(1) or (D) of rule
3745-20-04
of the Administrative Code, where asbestos was not removed prior to demolition,
keep asbestos-containing waste material adequately wet at all times during and
after demolition, and during handling, loading, transport and disposal at an
active waste disposal site. Asbestos-containing waste materials covered by this
paragraph shall either be sealed in leak-tight containers that comply with
paragraph (C) of this rule or may be transported in bulk by leak-tight
transport vehicles or containers that are securely covered or enclosed and
cause no visible emissions.
(3)
Process asbestos-containing waste material into nonfriable forms, as follows:
(a) Form all asbestos-containing waste
material into nonfriable pellets or other shapes
;
.
(b) Discharge no visible emissions to the
outside air from collection and processing operations, including incineration,
or use the method specified by rule
3745-20-12 of the
Administrative Code to clean emissions containing particulate asbestos material
before they escape to, or are vented to, the outside air.
(4) Use an alternative emission control and
waste treatment method that has received prior approval by the director
according to paragraph (A)(3) of rule
3745-20-04
of the Administrative Code.
(5) As
applied to demolition and renovation, the requirements of paragraphs (B) and
(C) of this rule do not apply to category I nonfriable asbestos-containing
material waste and category II nonfriable asbestos-containing material waste
that has not been crumbled, pulverized, or reduced to powder.
(C) Each waste generator shall
ensure that asbestos waste containers shall meet the following minimum
standards:
(1) All containers of
asbestos-containing waste material and wrapped material shall be labeled, using
permanent markings with letters of sufficient size and contrast so as to be
readily visible and legible, as follows:
"DANGER
CONTAINS ASBESTOS FIBERS
AVOID CREATING DUST
CANCER AND LUNG DISEASE HAZARD
R.Q., ASBESTOS
CLASS 9
NA 2212, III"
For wrapped material or material to be transported off the
facility site, label the containers or wrapped material with the name of the
waste generator and the location at which the waste was generated.
(2) Asbestos-containing waste
materials shall be sealed in plastic bags having a thickness of at least 0.006
inch (six-mils). A second clean, leak-tight plastic bag having a thickness of
at least 0.006 inch (six-mils) shall fully contain the first bag
; or
.
(3) A combination of a 0.006 inch (six-mils)
plastic bag and a leak-tight steel, plastic, or fiber drum, or reinforced
disposal box, leak-tight polypropylene woven fabric bag, or similar suitable
and durable container. Drums shall be fitted with a matching lid and lock-rims,
and boxes shall be banded and sealed with reinforced tape or in accordance with
manufacturers recommendations
; or
.
(4)
Facility components removed in units or sections, or materials that will not
fit into containers without additional breaking, shall be sealed with at least
0.012 inch (twelve mils) of leak-tight plastic or at least 0.010 inch (ten
mils) of leak-tight polypropylene woven fabric
;
or
.
(5) Asbestos-containing waste materials,
facility components, and contaminated debris may be disposed of using an
alternative disposal system or may be processed into nonfriable forms using an
alternative emission control and waste treatment system or method, which has
received the prior written approval of the director.
(a) To obtain approval for an alternative
asbestos waste disposal system or emission control and waste treatment method,
the applicant must submit
the following :
(i) Complete details regarding the reason
that an alternative disposal system or emission control and waste treatment
system or method is requested
; and
.
(ii)
The estimated quantity of materials to be disposed of or treated using this
system or method
; and
.
(iii) A
description of the disposal system or treatment method and an operating plan
describing the methods which are to be utilized to ensure that there are no
visible emissions during the collection, treatment, transport and disposal of
the asbestos-containing waste materials
;
and
.
(iv) The
name(s)
name and
address(es)
address of the waste disposal or treatment
site(s)
site
where the system will be utilized contingent upon the director's
approval.
(b) Any owner
or operator using an approved alternative waste disposal system or emission
control and waste treatment method shall operate the system in accordance with
the conditions of the director's approval.
(D) Each waste generator shall mark vehicles
used to transport asbestos-containing waste material during the loading and
unloading of waste so that the signs are visible.
(1) Display the following legend in the lower
panel of a sign which conforms to the requirements for twenty inch by fourteen
inch upright sign specified in
29 CFR
1910.145(d)(4):
"DANGER
ASBESTOS DUST HAZARD
CANCER AND LUNG DISEASE HAZARD
Authorized Personnel Only"
(2) In the legend use letter sizes and styles
of a visibility at least equal to the following specifications: one inch sans
serif, gothic or block, in the first and second line; and at least
three-fourths inches sans serif, gothic or block, in the third line; and
fourteen point gothic in the fourth line. Spacing between any two lines must be
at least equal to the height of the upper of the two lines.
(E) For all asbestos-containing
waste material transported off the facility site, each waste generator and
owner or operator of a waste disposal site shall maintain waste shipment
records. The waste shipment record shall be legible, complete, signed and dated
by the waste generator and waste disposal site operator as follows:
(1) The waste shipment record shall include
the following information:
(a) The name
and address of the work site or facility where
the asbestos- containing waste was generated, the mailing address, and
telephone number of the facility owner.
(b) The name, mailing address and telephone
number of the owner or operator (waste generator) responsible for handling,
packing, marking and labeling the asbestos-containing waste material.
(c) The name, mailing address, telephone
number and site location of the active waste disposal site designated by the
generator to receive the asbestos-containing waste material for
disposal.
(d) The name and address
of the local, state or USEPA regional agency responsible for administering the
asbestos NESHAP program.
(e) A
description of the asbestos-containing waste materials included in the waste
shipment.
(f) The number and type
of containers included in the waste shipment.
(g) The approximate volume of
asbestos-containing waste material included in the waste shipment in cubic
yards.
(h) Special handling
instructions or additional information relative to the waste shipment the waste
generator may specify.
(i) A
certification that the contents of this consignment are fully and accurately
described by proper shipping name and are classified, packed, marked, and
labeled, and are in all respects in proper condition for transport by highway
according to applicable international and government regulations.
(j) The name, address and telephone number of
the transporter.
(k) A
dated signature by the transporter to acknowledge
receipt of the asbestos-containing waste shipment described by the waste
generator in paragraphs (E)(1)(a) to (E)(1)(i) of this rule.
(l) A discrepancy indication space to be
completed by the owner or operator of the waste disposal site if any improperly
contained asbestos waste is observed or if there is any discrepancy in the
quantity of asbestos shipped and the quantity of asbestos waste received at the
asbestos waste disposal site.
(m) A
dated signature by the waste disposal site owner
or operator to acknowledge receipt of the asbestos-containing waste shipment
described by the waste generator in paragraphs (E)(1)(a) to (E)(1)(i) of this
rule except as noted in the discrepancy indication space.
(2) The waste generator and the owner or
operator of the waste disposal site shall conform to the following procedures:
(a) Before releasing the waste shipment for
off-site disposal the waste generator shall complete the information required
by paragraphs (E)(1)(a) to (E)(1) (h) of this rule, and sign and date on the
date of shipment, the certification required by paragraph (E)(1)(i) of this
rule.
(b) Upon receiving the waste
shipment the waste disposal site operator shall
do the
following :
(i) Sign and date the waste
shipment record making note of any improperly contained asbestos-containing
waste material or any discrepancy in the quantity or waste received on the
discrepancy indication space and provide a copy of the waste shipment record to
the transporter for the transporter's receipt and records.
(ii) As soon as possible and no longer than
thirty days after receipt of the waste, send the original completed copy of the
signed waste shipment record to the waste generator and retain the remaining
copy for the waste disposal site record.
(iii) Upon discovering a discrepancy between
the quantity of waste designated on the waste shipment records and the quantity
actually received, attempt to reconcile the discrepancy with the waste
generator. If the discrepancy is not resolved within fifteen days after
receiving the waste, immediately report the discrepancy in writing to the
local, state, or USEPA regional office responsible for administering the
asbestos NESHAP program for the waste generator, and, if different, the local,
state, or USEPA regional office responsible for administering the asbestos
NESHAP program for the disposal site. Describe the discrepancy and attempts to
reconcile it, and submit a copy of the waste shipment record along with the
report to Ohio EPA.
(3) When the waste generator does not receive
a completed waste shipment record signed by the owner or operator of the
designated disposal site, within thirty-five days of the date the waste was
accepted by the initial transporter, the waste generator shall contact the
transporter
and/or
or the owner or operator of the designated disposal
site to determine the status of the waste shipment.
(4) The waste generator shall report in
writing to the
appropriate Ohio EPA field office
where notification was submitted if a copy
of the waste shipment record, signed by the owner or operator of the designated
waste disposal site, is not received by the waste generator within forty-five
days of the date the waste was accepted by the initial transporter. Include in
the report the following information:
(a) A
copy of the waste shipment record for which a confirmation of delivery was not
received
; and
.
(b) A
cover letter signed by the waste generator explaining the efforts taken to
locate the asbestos waste shipment and the results of those efforts.
(5) The waste generator and waste
disposal site owner or operator, shall retain a copy of all waste shipment
records for at least two years.
(F) Each waste generator or facility owner
shall furnish upon request, and make available for inspection by the director
or the director's representative, all records required to be maintained under
this rule.
(G) When removing or
transporting asbestos-containing waste material to a disposal site, each owner
or operator of any demolition or renovation operation to whom this rule applies
shall prepare and secure any load of asbestos-containing waste material in a
manner that prevents any visible emissions, load loss, and spillage or leakage
of liquids.