[Comment: For dates and availability of non-regulatory
government publications, publications of recognized organizations and
associations, federal rules, and federal statutory provisions referenced in
this rule, see paragraph (JJ) of rule
3745-21-01
of the Administrative Code titled "referenced materials."]
(A) General provisions.
(1) The methods and procedures of this rule
apply to sources governed by rule
3745-21-09
of the Administrative Code.
(2) Use
of an alternative test method, in lieu of one of the USEPA's approved test
methods or in lieu of other methods specified in this rule, shall be approved
by the USEPA as a revision of the state implementation plan.
(3) The results of any compliance testing
required by the director for tests conducted pursuant to paragraphs (C) to (F)
and (L) of this rule shall not be accepted unless the Ohio EPA district office
or local air agency has been notified of the intent to test in accordance with
paragraph (A)(4) of this rule not less than thirty days before the proposed
initiation of the testing.
(4) Any
person notifying the Ohio EPA district office or local air agency of a proposed
emissions compliance test shall include as part of the notification the
following information:
(a) A statement
indicating the purpose of the proposed test and the applicable paragraph of
rule
3745-21-09
of the Administrative Code.
(b) A
detailed description of the facility to be tested.
(c) A detailed description of the test
procedures, equipment and sampling sites.
(d) A timetable, setting forth the dates on
which the following will occur:
(i) The
testing will be conducted.
(ii) The
final test report will be submitted (not later than thirty days after
completion of on-site sampling).
(5) For any source compliance determination,
the owner or operator of the source shall be responsible for providing the
following:
(a) Sampling ports, pipes, lines,
or appurtenances for the collection of samples and data required by the test
procedures.
(b) Safe access to the
sample and data collection locations.
(c) Light, electricity, and other utilities
required for sample and data collection.
(B) Method for the determination of volatile
organic compound content, solids content, and density of surface coatings and
inks.
(1) This method applies to coatings,
inks or other coating materials employed in a coating line, printing line or
other operation. For purposes of this method "coating" shall also mean "ink" or
other coating material.
(2) Any
determination of VOC content, solids content, or density of a coating shall be
based on the coating as employed (as applied), including the addition of any
thinner or viscosity reducer to the coating.
(3) When a sample of a coating is obtained
for analysis by any of the procedures described in this method, the amount of
the sample shall be at least one quart. The sample shall be placed in an
air-tight container. When multiple package coatings are sampled, separate
samples of each component shall be obtained.
(4) Using either the procedures set forth in
USEPA method 24 (for coatings), USEPA method 24A (for flexographic and
rotogravure printing inks and related coatings) and 40 CFR Part
63 , Subpart
PPPP, Appendix A (for reactive adhesives), or the coating formulation data from
the coating manufacturer and coating user, the following shall be determined,
where appropriate:
DC = density of coating, in pounds of
coating per gallon of coating.
DVM = density of volatile matter in
coating, in pounds of volatile matter per gallon of volatile matter.
VS = volume fraction of solids
(nonvolatile matter) in coating, in gallon of solids per gallon of
coating.
VVM = volume fraction of volatile matter
in coating, in gallon of volatile matter per gallon of coating.
VW = volume fraction of water in
coating, in gallon of water per gallon of coating.
WS = weight fraction of solids
(nonvolatile matter) in coating, in pound of solids per pound of
coating.
WVM = weight fraction of volatile matter
in coating, in pound of volatile matter per pound of coating. If this weight
fraction is determined by ASTM D2369-04
D2369, "Standard Test Method for Volatile Content of
Coatings," the drying conditions shall be one hundred ten degrees Celsius for
one hour, except where otherwise authorized by the director based on an
alternate analytical procedure that is satisfactorily demonstrated to the
director by the coating manufacturer to be more representative of the actual
cure mechanism of the coating.
WW = weight fraction of water in
coating, in pound of water per pound of coating.
(5) If the coating contains a volatile matter
other than VOC or water, the identity and content of such volatile matter may
be determined using either standard gas chromatographic techniques or coating
formulation data from the coating manufacturer and coating user. The density of
such volatile matter may be determined using either the procedures set forth in
ASTM
D1475-98(2012)
D1475 or data from reference texts. For purposes of
this method, such volatile matter shall be referred to as exempt solvent. The
following may be determined, where appropriate:
DES = density of exempt solvent, in
pounds of exempt solvent per gallon of exempt solvent.
VES = volume fraction of exempt solvent
in coating, in gallon of exempt solvent per gallon of coating.
WES = weight fraction of exempt solvent
in coating, in pound of exempt solvent per pound of coating.
(6) The weight fraction
W
VOC of VOC in a coating and the volume fraction
V
VOC of VOC in a coating shall be calculated as follows,
where appropriate:
WVOC = WVM -
WW - WES
VVOC = VVM -
VW - VES
(7) The VOC content of a coating can be
expressed as follows:
CVOC,1 = VOC content in pounds of VOC
per gallon of coating.
CVOC,2 = VOC content in pounds of VOC
per gallon of coating, excluding water and exempt solvents.
CVOC,3 = VOC content in pounds of VOC
per gallon of solids.
CVOC,4 = VOC content in pounds of VOC
per pound of solids.
CVOC,5 = VOC content in percentage VOC
by volume of the coating, excluding water and exempt solvents.
CVOC,6 = VOC content in percentage VOC
by volume of the volatile matter.
CVOC,7 = VOC content in percentage VOC
by weight of the coating.
(8) The VOC content of a coating shall be
calculated as follows, where appropriate:
CVOC,1 =
(DC)(WVOC)
CVOC,2 =
(DC)(WVOC) /
(VS + VVOC)
CVOC,3 =
(DC)(WVOC) /
VS
CVOC,4 = WVOC /
WS
CVOC,5 =
(100)(VVOC) / (VS +
VVOC)
CVOC,6 =
(100)(VVOC) / VVM
CVOC,7 =
(100)(WVOC)
(9) The weighted average VOC content of the
coatings employed during a specified time period t shall be calculated as
follows, where appropriate:
Click to
view image
where:
A = subscript denoting that the indicated VOC content is a
weighted average of the coatings employed during time period t.
LC = liquid volume of coating employed
during time period t, in gallons of coating.
MC = mass (weight) of coating employed
during time period t, in pounds of coating.
i = subscript denoting a specific coating employed during time
period t.
n = total number of coatings employed during time period
t.
t = time period specified for the weighted average VOC
content.
(10) The density
of the VOC content of a coating may be determined using either the procedures
set forth in ASTM
D1475-98(2012)
D1475 or data from reference texts. If ASTM
D1475-98(2012)
D1475 is employed, the density shall be the arithmetic
average of three determinations.
(11) In the event of a dispute between
coating formulation data and data obtained by analytical procedures, the data
obtained by analytical procedures shall be employed, except as otherwise
provided in paragraph (B)(12) of this rule.
(12) If a VOC content value obtained by
analytical procedures is higher than a VOC content value obtained by
formulation data due to any VOC that is formed during baking or curing (i.e.,
cure volatiles), then the VOC content of the portion of the coating not subject
to curing or baking shall be based on formulation data and the VOC content of
the portion of the coating subject to curing or baking shall be based on
analytical procedures. The portion of the coating subject to curing or baking
shall be equal to the measured transfer efficiency for the coating applicator
and object being coated. The approach described in this paragraph for
determining the VOC content of a coating may be used only when the applicable
VOC limitation is expressed in terms of pounds of VOC per gallon of deposited
solids and the transfer efficiency test method is specified in this rule or
rule
3745-21-09
of the Administrative Code. Also, in cases where analytical results and
formulation data are combined for a waterborne coating, the interlaboratory
precision adjustments specified in the analytical procedures shall not be
applied to the analytical results.
(C) Method for the determination of VOC
concentration, VOC mass emission rate and VOC control equipment efficiency.
(1) The provisions of this paragraph are
generally applicable to the test methods employed to determine the VOC
concentration and VOC mass emission rate for a gas stream or exhaust vent and
the collection or control efficiency for any control equipment designed,
installed, and operated for the purpose of reducing the emission of VOC. For
purposes of this paragraph, "vapor collection system" also means capture system
and "vapor control system" also means control system or control
device.
(2) The concentration of
VOC in a gas stream or exhaust vent shall be determined by utilizing the
following methods:
(a) USEPA method 25 or
USEPA method 25A, as appropriate, for sources specified in paragraphs (C) to
(L), (P), (R), (S), (U), (W) to (Y), (FF), (GG), (LL) to (NN) [if the control
efficiency compliance option in (LL), (MM) or (NN) is chosen] and, (PP), (SS),
(VV)(2), (XX)(1), (YY), (ZZ)(1)(a), (AAA)(1), and (BBB) of rule
3745-21-09
of the Administrative Code; or
(b)
USEPA method 18 or USEPA method 25A, as appropriate, for sources specified in
paragraphs (O)(3)(c)(iv), (O)(4)(a)(ii), (CC) to (EE), and (LL) to (NN) [if the
ppmv compliance option in (LL), (MM) or (NN) is chosen] of rule
3745-21-09
of the Administrative Code.
(3) The following procedures shall be
included in any source testing or determination where applicable:
(a) The source shall be operated at or near
maximum operating capacity during any testing and the measurement of the
operating rate shall be made in a manner acceptable to the Ohio EPA.
(b) The VOC content of any coatings employed
shall be sampled and analyzed in accordance with paragraph (B) of this
rule.
(c) The capture efficiency of
any vapor collection system used to transport the VOC emissions from their
point of origin to the vapor control system shall be determined in accordance
with USEPA methods 204 to 204F or the alternative capture efficiency testing
protocols specified in the USEPA, Office of Air Quality Planning and Standards
document entitled "Guidelines for determining capture efficiency."
(d) The control efficiency of any vapor
control system used to reduce the emission of VOC shall be based upon an
emissions test or a recovery test. For a vapor control system that destroys VOC
(e.g., an incineration system), either the streams entering and leaving the
vapor control system shall be tested or, if acceptable to the director, the
amount of VOC employed shall be measured and the gas stream leaving the vapor
control system shall be tested. For a vapor control system that recovers VOC
(e.g., a carbon adsorption system), either the gas streams entering and leaving
the vapor control system shall be tested or, if acceptable to the director, the
amounts of VOC employed and recovered or, employed and emitted, shall be
measured or tested.
(e) For the
testing of a gas stream vented to a vapor control system, samples shall be
taken simultaneously at the inlet and the outlet of the vapor control
system.
(f) For the testing of a
gas stream, the sampling location, volumetric flow rate, molecular weight,
carbon dioxide and oxygen contents, excess air, and water vapor content shall
be determined in accordance with USEPA methods 1, 1A, 2, 2A, 2C, 2D, 3 and
4.
(g) For gas streams tested by
USEPA method 25 or 25A, the VOC emission rate shall be based upon the average
of three test runs. Each run shall have a minimum duration of one hour and a
minimum sample volume of .003 dry standard cubic meter, except that shorter
sampling times or smaller volumes, when necessitated by process variables, may
be found acceptable.
(h) The
control efficiency of the vapor control system shall be the per cent reduction
in mass emissions of VOC between the inlet and the outlet of the vapor control
system. If this efficiency is based upon an emissions test utilizing USEPA
method 25 or 25A, the mass emissions of VOC as carbon shall be employed in the
efficiency determination.
(i) The
capture efficiency of the vapor collection system shall be the per cent of
total mass emissions of VOC emitted from the source which are vented to the
vapor control system. If this efficiency is based upon an emissions test
utilizing USEPA method 25 or 25A, the mass emissions of VOC as carbon shall be
employed in the efficiency determination.
(j) The overall control efficiency (in per
cent) of any control equipment for VOC emissions shall be the vapor capture
efficiency multiplied by the vapor control efficiency and divided by one
hundred.
(k) The total mass
emission rate of VOC from a source equipped with control equipment shall be the
sum of VOC emissions from the vapor control system, VOC emissions not collected
by the vapor collection system and VOC emissions from any losses associated
with the vapor collection system and vapor control system.
(4) The VOC mass emissions rate
for a gas stream tested by USEPA method 18 shall be calculated as follows:
Click to
view image
where:
ES = VOC mass emission rate for the gas
stream, in kilograms of VOC per hour (kg VOC/hr).
K = 2.494 × 10-6 (gram
mole-kilogram-minute per standard cubic meter-gram-ppmv-hour).
where the standard temperature for gram-mole per standard cubic
meter is twenty degrees Celsius.
QS = volumetric flow rate of gas stream,
in dry standard cubic meters per minute, at a standard temperature of twenty
degrees Celsius.
Ci = concentration of sample component
i, in ppmv, dry basis.
Mi = molecular weight of sample
component i, in grams per gram-mole.
i = subscript denoting a specific sample component, which is a
VOC, in the gas stream.
n = total number of sample components, which are VOC, in the
gas stream.
(5) The mass
emission rate of VOC as carbon for a gas stream tested by USEPA method 25 shall
be calculated as follows:
ES = K
CSQS
where:
Es = mass emission rate of VOC as carbon
for the gas stream, in kilograms of carbon per hour (kg C/hr).
K = 1 × 10-6 kilograms per
milligram.
CS = concentration of VOC as carbon in
the gas stream, in milligrams of carbon per dry standard cubic meter.
QS = volumetric flow rate of the gas
stream, in dry standard cubic meters per hour.
(6) To convert a mass emission rate from
kilograms per hour to pounds per hour, multiply the mass emission rate in
kilograms per hour by 2.2046.
(7)
To convert a mass emission value from VOC as carbon to VOC, divide the mass
emission value of VOC as carbon by the weight fraction of carbon in the average
molecular weight of the VOC emission. The determination of this weight fraction
of carbon may be based on standard analytical techniques or material
formulation data.
(D)
Method for the determination of VOC emissions from solvent metal cleaning:
(1) This method is applicable to determining
VOC emissions from solvent metal cleaning equipment.
(2) The purpose of this method is to
quantify, by material balance, the amount of solvent input into a degreaser
over a sufficiently long period of time so that an average emission rate can be
computed.
(3) The following
procedure shall be followed to perform a material balance test:
(a) Clean the degreaser sump before
testing.
(b) Record the amount of
initial and make-up solvent added to the tank with a flow meter or other
means.
(c) Record the type and
amount or weight of work load degreased each day.
(d) At the end of the test run, pump out the
used solvent and measure the amount with a flow meter or other means. Also,
estimate the volume of metal chips and other material remaining in emptied
sump, if significant.
(e) Bottle a
sample of the used solvent and analyze it to find the per cent that is oil and
other contaminants. The oil and solvent proportions can be estimated by
weighing samples of used solvent before and after boiling off the solvent.
Compute the volume of oils in the used solvent. The volume of solvent displaced
by this oil along with the volume of make-up solvent added during operations is
equal to the amount of VOC emissions.
(4) The following procedure can be followed
to perform a material balance test in lieu of the procedure in paragraph (D)(3)
of this rule:
(a) Clean the degreaser sump
before testing.
(b) Record the
amount of initial and make-up solvent added to the tank as measured with a flow
meter or other means.
(c) Record
the type and amount or weight of work load degreased over the period of the
test.
(d) Record the amount of used
solvent pumped out of the tank for disposal as measured with a flow meter or
other means.
(e) Bottle a sample of
the used solvent and analyze it to find the per cent that is oil and other
contaminants.
(f) The VOC emissions
from solvent metal cleaning equals the total solvent added to the tank minus
the solvent contained in the used solvent being disposed.
(E) Method for the determination
of VOC emissions from bulk gasoline terminals.
(1) This method is applicable to determining
the VOC emission rates at a bulk gasoline terminal employing a vapor collection
system and either a continuous or intermittent vapor control system at a
loading rack.
(2) The VOC emission
rates shall be determined in accordance with the methods and procedures
contained in
40 CFR
60.503(b), (c),
(e) and (f) of "Subpart XX -Standards of
Performance for Bulk Gasoline Terminals."
(3) During any test, all loading racks shall
be open for each product line which is controlled by the system under test.
Simultaneous use of more than one loading rack shall occur to the extent that
such use would normally occur.
(4)
Simultaneous use of more than one dispenser on each loading rack shall occur to
the extent that such use would normally occur.
(5) Dispensing rates shall be set at the
maximum rate at which the equipment is typically operated. Automatic product
dispensers are to be used according to normal operating practices.
(6) Applicable operating parameters of the
vapor control system shall be monitored to demonstrate that the control unit is
operating at design levels. Delivery devices shall be leak free.
(7) For each gasoline tank truck loaded
during the test period, all potential sources of leaks shall be checked in
accordance with the method specified in paragraph (K) of this rule. The tank
identification number, the latest leak check certification date, and the
location and highest detector reading for each incident of leakage shall be
recorded.
(8) During each test, all
potential sources of leaks in the vapor collection and control systems shall be
monitored in accordance with the method specified in paragraph (K) of this
rule. The location and highest detector reading for each incident of leakage
shall be recorded.
(F)
Method for the detection of leaks of VOC from petroleum refinery equipment and
organic chemical manufacturing equipment.
(1)
This method is applicable to the detection of leaks of VOC into the ambient air
from petroleum refinery equipment and any chemical manufacturing equipment
subject to paragraph (T) or (DD) of rule
3745-21-09
of the Administrative Code.
(2) The
detection of leaks shall be determined in accordance with the test procedure
set forth in USEPA method 21.
(3)
The calibration gases shall conform to the following:
(a) Zero air, which consists of less than ten
ppmv of hydrocarbon in air.
(b) A
mixture of air and methane or n-hexane at a concentration of approximately, but
less than, ten thousand ppmv of methane or n-hexane.
(4) The leak detection instrument shall be
calibrated before use on each day of its use.
(G) Standard method for the determination of
the leak tightness of gasoline tank trucks (method G).
(1) This method is applicable to determining
the leak tightness of gasoline tank trucks which are equipped with piping,
hoses and other devices for the collection or return of gasoline vapors during
the transfer of gasoline at a gasoline dispensing facility, bulk gasoline plant
or bulk gasoline terminal.
(2) The
leak tightness of a gasoline tank truck shall be determined in accordance with
the test procedure set forth in USEPA method 27. For the pressure test, the
initial pressure shall be 18.0 inches of water. For the vacuum test, the
initial vacuum shall be 6.0 inches of water.
(3) If any gasoline tank truck or compartment
of a gasoline tank truck sustains either a pressure decrease greater than 3.0
inches of water over five consecutive minutes for the pressure test or a
pressure increase greater than 3.0 inches of water over five consecutive
minutes for the vacuum test, the tank truck is not leak tight. If not leak
tight, repair the tank truck as necessary and repeat the entire test procedure
specified in paragraph (G)(2) of this rule until the gasoline tank truck or
compartment passes the test.
(H) [Reserved.]
(I) Method for the determination of seal gaps
in an external floating roof tank.
(1) This
method is applicable to determining the width and area of any gaps between the
wall of an external floating roof tank and a seal which is around the
circumference of the external floating roof.
(2) The width of any seal gap is the distance
between the seal and the tank wall. It is determined by using probes of various
widths to accurately measure the actual distance from the seal to the tank
wall.
(3) The area of any seal gap
is determined by multiplying the width of the seal gap, as determined in
paragraph (I)(2) of this rule, by the circumferential length of the
gap.
(4) The total seal gap area is
the accumulated area of all gaps which are greater than 0.125 inch in
width.
(J) Method for
the determination of the perchloroethylene content of wastes at a dry cleaning
facility which uses perchloroethylene.
(1) The
method is applicable to determining the perchloroethylene content in per cent
by weight for waste at a dry cleaning facility from any distillation operation
which distills perchloroethylene and from any diatomaceous earth filter which
filters perchloroethylene.
(2) The
perchloroethylene content of the waste in per cent by volume is determined in
accordance with the procedure in ASTM
D322-97(2012)
D322,
and is calculated as the diluent content in that procedure.
(3) The density of the waste is determined by
weighing a known volume of the waste and is calculated as the net weight of the
waste in pounds divided by the volume of the waste in gallons.
(4) The perchloroethylene content of the
waste in per cent by weight is calculated as the product of the waste diluent
content and 13.55, divided by the waste density.
(K) Method for the detection of leaks of
gasoline vapors from vapor control systems, vapor collection systems, vapor
balance systems, gasoline barges and gasoline tank trucks.
(1) This method is applicable to the
detection of leaks of gasoline vapors into the ambient air from the following:
(a) Vapor control systems, vapor collection
systems, and vapor balance systems at barge loading facilities (for gasoline),
bulk gasoline terminals, bulk gasoline plants, and gasoline dispensing
facilities.
(b) Gasoline barges and
gasoline tank trucks during loading, providing the vapor control system, vapor
collection system, or vapor balance system which is connected to the gasoline
barge or gasoline tank truck does not create a back pressure greater than
eighteen inches of water gauge pressure.
(2) This method describes the procedures to
be followed for detecting leaks of gasoline vapors by means of a portable
hydrocarbon gas analyzer, which is calibrated to read in per cent of the lower
explosive limit as propane.
(3) The
following equipment are to be used:
(a) A
liquid manometer, or equivalent device, capable of measuring up to twenty-five
inches of water gauge pressure with a precision of plus or minus 0.1 inch of
water.
(b) A portable hydrocarbon
gas analyzer which conforms to the following:
(i) Is equipped with a sampling line of
sufficient length for easy maneuverability during testing and a sampling probe
having an internal diameter of 0.25 inch.
(ii) Is certified as safe for operation in
explosive atmospheres.
(iii) Has a
minimum range of zero to one hundred per cent of the lower explosive limit as
propane.
(iv) Has a response time
for full-scale deflection of less than eight seconds with sampling line and
probe attached.
(4) The portable hydrocarbon gas analyzer is
calibrated with 2.2 per cent propane by volume in air (or equivalent
calibration gas) for one hundred per cent of the lower explosive limit
according to the procedures and frequency specified by the
manufacturer.
(5) The test
procedures for detecting leaks are the following:
(a) Connect the liquid manometer to a
pressure tap in the vapor control system, vapor collection system, or vapor
balance system as close as possible to the connection with the gasoline barge
or gasoline tank truck.
(b) Record
the pressure periodically during loading of the gasoline barge or gasoline tank
truck.
(c) Check with the portable
hydrocarbon gas analyzer all potential leak sources on the gasoline barge or
gasoline tank truck during loading and on the vapor control system, vapor
collection system, or vapor balance system by doing the following:
(i) Maintaining the probe's inlet about one
inch from the potential leak source in the path of (parallel to) the vapor flow
from a leak.
(ii) Moving the probe
slowly around the periphery of the potential leak source to locate the point of
highest meter response.
(iii)
Blocking as much as possible the wind from the area being monitored.
(d) Record the location of leakage
and the highest detector reading for each incidence of leakage.
(L) Method for the
determination of the emission of volatile organic compounds from a dryer at a
petroleum dry cleaning facility.
(1) This
method is applicable to determining the volatile organic compound emission rate
of a dryer containing articles cleaned in petroleum solvent at a dry cleaning
facility.
(2) The dryer shall be
tested under normal operating conditions for at least thirty dryer loads that
total not less than four thousand pounds dry weight of articles cleaned. The
dryer loads shall represent a normal range of variations in fabrics, solvents,
load weights, temperatures, flow rates, and process deviations. Each dryer load
shall be tested in accordance with paragraph (L)(3) or (L)(4) of this
rule.
(3) For each dryer load the
following shall be conducted and recorded:
(a)
Determine the average stack gas dry volumetric flow rate V (in dry standard
cubic feet per hour) in accordance with USEPA methods 1 and 2.
(b) Determine the average organic
concentration C in the stack (in ppmv as propane) in accordance with USEPA
method 25A in which the flame ionization analyzer is calibrated with propane
standards.
(c) Determine the ratio
R of the flame ionization analyzer's response to a given parts per million by
volume concentration of propane to
its
the response to the same parts per million by volume
concentration of the volatile organic compounds present in the stack
gas.
(d) Determine the molecular
weight M (in pounds per pound-mole) of the volatile organic compounds present
in the stack gas. Such determination shall be based on data from the
manufacturer of the cleaning solvent or on standard analytical
techniques.
(e) Measure and record
the weight Wa (in pounds dry weight) of the articles to be cleaned.
(f) Calculate the weight WVOC (in pounds) of
the volatile organic compounds emitted into the ambient air using the following
equation:
WVOC = V × C × R × M
(4) For each dryer load the
following shall be conducted and recorded:
(a) All weights shall be measured to the
nearest 0.5 pound or less on a scale that is accurate to 0.5 pound at weights
of up to two hundred pounds.
(b)
Measure and record the weight Wa (in pounds) of the
articles to be cleaned.
(c) Measure
and record the initial weight Wi (in pounds) of the
articles to be dried after the washing cycle.
(d) Measure and record the final weight
Wf (in pounds) of the articles removed from the dryer
after the drying cycle.
(e) Measure
and record the weight Wr (in pounds) of any recovered liquid
materials.
(f) Calculate the weight
WVOC (in pounds) of the volatile organic compounds emitted into the ambient air
using the following equation:
WVOC = Wi -
Wf - Wr
(5) The dryer's volatile organic
compound emission rate (in pounds per one hundred pounds dry weight of articles
cleaned) shall be calculated for the combined dryer loads tested under this
method as equal to one hundred multiplied by the sum total of
WVOC and divided by the sum total of
Wa.
(M) Method for the determination of the
amount of volatile organic compounds contained in filtration waste at a
petroleum dry cleaning facility.
(1) This
method is applicable to determining the amount of volatile organic compounds
contained in the waste from a solvent filter used to filter petroleum solvent
at a dry cleaning facility.
(2) The
solvent filter shall be tested under normal operating conditions for at least
three time periods according to the procedures specified in paragraph (M)(3) of
this rule.
(3) The test procedures
for each time period are as follows:
(a) A
time period consists of the time immediately after the removal of waste from
the solvent filter up to the next removal of waste.
(b) Record the date and time of the start of
the time period.
(c) Record during
the time period the weight of articles being cleaned in any washer connected to
the solvent filter.
(d) Record the
weight of the waste from the solvent filter at the end of the time period, in
pounds.
(e) Collect in a sealed
container, which is impervious to petroleum solvent, about two pounds of the
waste from the solvent filter at the end of the time period.
(f) Record the date and time of the end of
the time period.
(g) Conduct a
laboratory analysis of the waste collected in the sealed container according to
the procedures specified in paragraph (M)(4) of this rule.
(4) The procedures for the
laboratory analysis of the collected filtration waste are as follows:
(a) Determine the weight WS (in grams of a
sample of approximately fifty milliliters of the filtration waste).
(b) Determine the volume VS (in milliliters)
of the diluent content of that sample in accordance with ASTM
D322-97(2012)
D322.
(c)
Calculate the sample's diluent content D
s (fraction
diluent by weight) using the following equation:
Ds = (0.78 x
Vs) / Ws
Click to
view image
where 0.78 is the typical density of petroleum solvent in grams
per milliliter.
(5) For the test conducted under paragraphs
(M)(2), (M)(3) and (M)(4) of this rule, the amount of VOCs contained in the
filtration waste is calculated using the following equation:
X =
((W1D1 +
W2D2 +
W3D3) /
(A1 + A2 +
A3)) x 100
Click to
view image
where:
X = amount of VOCs in the filtration waste, in pounds of VOC
per one hundred pounds dry weight of articles cleaned.
A = total weight of articles cleaned during the time period
indicated, in pounds dry weight.
D = diluent content of the sample of filtration waste for the
time period indicated, in fraction diluent by weight (pounds of diluent per
pound of filtration waste).
W = total weight of filtration waste for the time period
indicated.
Subscripts 1, 2, and 3 identify the time period of the
test.
(N) Method
for the determination of the length of time to operate the recovery cycle of a
solvent recovery dryer at a petroleum dry cleaning facility.
(1) This method is applicable to determining
the length of time for operating the solvent recovery cycle of a solvent
recovery dryer at a petroleum dry cleaning facility in order to assure that the
flow rate of recovered petroleum solvent at the termination of solvent recovery
cycle is no greater than fifty milliliters per minute.
(2) The dryer shall be tested under normal
operating conditions for a duration of no less than two weeks during which no
less than one-half of the dryer loads shall be monitored for their final
recovered solvent flow rate.
(3)
The suggested point for measuring the flow rate of recovered solvent is from
the outlet of the solvent-water separator. Near the end of the recovery cycle,
the entire flow of recovered solvent is diverted to a graduated cylinder. As
the recovered solvent collects in the graduated cylinder, the elapsed time is
monitored and recorded in periods greater than or equal to one minute. At the
same time, the volume of solvent in the graduated cylinder is monitored and
recorded to determine the volume of recovered solvent that is collected during
each time period. The recovered solvent flow rate is calculated by dividing the
volume of solvent collected per period by the length of time elapsed during the
period and converting the result with appropriate factors into units of
milliliters per minute. The recovery cycle and the monitoring procedure is
continued until the flow rate of solvent is less than or equal to fifty
milliliters per minute. The date, the type of articles cleaned, and the total
length of the recovery cycle shall be recorded for each dryer load being
monitored.
(O) Method
for the determination of equipment in VOC service and in light liquid service.
(1) This method is applicable to equipment at
a petroleum refinery or a process unit subject to paragraph (T) or (DD) of rule
3745-21-09
of the Administrative Code.
(2) Any
piece of equipment is presumed to be in VOC service, unless the owner or
operator demonstrates that the piece of equipment is not in VOC service
according to the following provisions:
(a)
The piece of equipment is considered not in VOC service if it can be determined
that the VOC content of the process fluid, which is contained in or contacts
the piece of equipment, can be reasonably expected never to exceed ten per cent
by weight.
(b) For purposes of
determining the VOC content of a process fluid, procedures that conform to the
general methods described in ASTM
E168-06
E168, ASTM
E169-04(2009)
E169, and ASTM
E260-96(2011)
E260
shall be used.
(c) The owner or
operator may use engineering judgment rather than the procedures contained in
paragraph (O)(2)(b) of this rule to demonstrate that the VOC content of a
process fluid does not exceed ten per cent by weight, provided the VOC content
clearly does not exceed ten per cent by weight. In the event the Ohio EPA or
the USEPA has a disagreement with an engineering judgment, paragraph (O)(2)(b)
of this rule shall be used to resolve the disagreement.
(3) A piece of equipment is in light liquid
service if it contains or is in contact with a process fluid that meets all of
the following conditions:
(a) The process
fluid is a liquid at operating conditions.
(b) The vapor pressure of one or more of the
pure components within the process fluid is greater than 0.04 pound per square
inch at sixty-eight degrees Fahrenheit. Vapor pressures may be obtained from
standard reference texts or may be determined by the method in ASTM
D2879-10
D2879.
(c)
The total concentration of the pure components having a vapor pressure greater
than 0.04 pound per square inch at sixty-eight degrees Fahrenheit is equal to
or greater than twenty per cent by weight.
(P) Method for the determination of the net
heating value of a gas, the actual exit velocity for a flare, and the maximum
permitted velocity for an air-assisted flare.
(1) This method is applicable to the
following:
(a) Any flare subject to paragraph
(DD) of rule
3745-21-09
of the Administrative Code.
(b) Any
process vent stream subject to paragraph (EE) of rule
3745-21-09
of the Administrative Code.
(2) The net heating value of gas being
combusted in a flare or being vented from a process vent stream shall be
calculated using the following equation:
where:
Click to
view image
HT = net heating value of the sample, in
mega joules per standard cubic meter (MJ/scm), where the net enthalpy per mole
of offgas is based on combustion at twenty-five degrees Celsius and seven
hundred sixty millimeters of mercury, but the standard temperature for
determining the volume corresponding to one mole is twenty degrees
Celsius.
k = constant, 1.740 × 10-7
(megajoule-gram mole per parts per million-standard cubic meter-kilocalorie),
where the standard temperature for gram-mole per standard cubic meter (g
mole/scm) is twenty degrees Celsius.
Ci = concentration of sample component i
in ppmv, as measured by the procedures in USEPA method 18, and ASTM
D1946-90(2011)
D1946 reported on a wet basis.
Hi = net heat of combustion of sample
component i, in kilocalories per grammole. The heat of combustion may be
determined using the procedures in ASTM D2382-76
D2382 if
published values are not available or cannot be calculated.
i = subscript denoting a specific component in the
sample.
n = total number of components within the
sample.
(3) The actual exit
velocity of a flare shall be calculated by dividing the volumetric flow rate
(in units of standard temperature and pressure) of the flare header or headers
that feed the flare, as determined by USEPA methods 2, 2A, 2C, or 2D as
appropriate, by the unobstructed (free) cross-sectional area of the flare tip,
as determined by design and engineering principles.
(4) The maximum permitted velocity of an
air-assisted flare shall be determined by the following equation:
Vmax = 8.706 + 0.7084(HT)
where:
Vmax = maximum permitted velocity of an
air-assisted flare, in meters per second (m/sec).
HT = the net heating value as determined
in paragraph (P)(2) of this rule.
(5) To express the net heating value of a gas
in Btu per standard cubic foot, multiply HTby 26.84.
(6) To express a velocity in feet per second,
multiply the velocity in meters per second by 3.281.
(Q) Method for the detection of leaks of
gasoline vapors from a vapor control system installed at a gasoline dispensing
facility (static leak test).
(1) This method
is applicable to quantifying the vapor tightness of a vapor balance system or a
vacuum assist control system installed at a gasoline facility.
(2) This method describes the procedures to
be followed for detecting leaks of gasoline vapors by pressurizing the entire
vapor recovery control system to two inches of water column and then allowing
the system pressure to decay for five minutes. The acceptability of the final
pressure is based upon the vapor system volume or ullage space. The allowable
five minute final pressure is based upon the gasoline tank ullage, pressure
decay equations, and the number of affected nozzles.
(3) The equipment, procedures, and pressure
decay leak criteria are specified in appendix A to this rule.
(R) Method for the determination
of the dynamic pressure performance for a vapor control system installed at a
gasoline dispensing facility (dynamic pressure performance test).
(1) This method is applicable to determining
the dynamic pressure at known dispensing flow rates for a vapor control system
installed at a gasoline dispensing facility. This method is used to quantify
the back pressure and detect liquid obstructions in the vapor path leading from
the dispensing nozzle to the gasoline storage tank.
(2) This method describes the procedures to
be followed in simulating the dynamic back pressures associated with known
gasoline dispensing rates and liquid blockages by passing nitrogen through the
vapor control system at three flow rates after liquid gasoline has been
introduced into the vapor return piping.
(3) The equipment, procedures, and dynamic
pressure performance criteria are identified in appendix B to this rule. The
post test inspection form, as required by paragraph (DDD)(2)(c) of rule
3745-21-09
of the Administrative Code, is contained in appendix C to this rule.
(S) Inspection and maintenance
requirements for catalytic incinerators. An inspection and maintenance plan
shall be developed, maintained on-site, and made readily available upon the
request of the appropriate Ohio EPA district office or local air agency. At a
minimum, the plan shall include the following:
(1) Annual sampling and analysis of the
catalyst activity (i.e., conversion efficiency) following the manufacturer's or
catalyst supplier's recommended procedures.
(2) Monthly inspection of the oxidizer system
including the burner assembly and fuel supply lines for problems.
(3) Annual internal and monthly external
visual inspection of the catalyst bed to check for channeling, abrasion, and
settling. If problems are found, corrective action consistent with the
manufacturer's recommendations shall be implemented and a new performance test
to determine destruction efficiency in accordance with paragraph (C) of this
rule shall be conducted.