Ohio Admin. Code 3745-34-55 - Logging, sampling, and testing prior to new well operation
(A) During the
drilling and construction of a new Class I hazardous waste injection well,
appropriate logs and tests shall be run to determine or verify the depth,
thickness, porosity, permeability, and rock type of, and the salinity of any
entrained fluids in, all relevant geologic units to assure conformance with
performance standards of rule
3745-34-54 of the Administrative
Code and to establish accurate baseline data against which future measurements
may be compared. A descriptive report interpreting results of such logs and
tests shall be prepared by a knowledgeable log analyst and submitted to the
director. Such logs and tests shall include:
(1) Deviation checks during drilling on all
holes constructed by drilling a pilot hole which is enlarged by reaming or
another method. Such checks shall be at sufficiently frequent intervals to
determine the location of the bore hole and to assure that vertical avenues for
fluid movement in the form of diverging holes are not created during drilling;
and
(2) Such other logs and tests
as may be required by the director after taking into account the availability
of similar data in the area of the drilling site, the construction plan, and
the need for additional information that may arise from time to time as the
construction of the well progresses. At a minimum, the following logs shall be
required in the following situations:
(a)
Upon installation of the surface casing:
(i)
Resistivity, spontaneous potential, and caliper logs before the casing is
installed; and
(ii) A cement bond
and variable density log, and a temperature log after the casing is set and
cemented.
(b) Upon
installation of the long string casing;
(i)
Resistivity, spontaneous potential, porosity, caliper, gamma ray, and fracture
finder logs before the casing is installed; and
(ii) A cement bond and variable density log,
and a temperature log after the casing is set and cemented.
(c) The director may allow the use
of an alternative to the above logs when an alternative will provide equivalent
or better information; and
(3) A mechanical integrity test consisting
of:
(a) A pressure test with liquid or gas;
and
(b) A radioactive tracer
survey; and
(c) A temperature or
noise log; and
(d) A casing
inspection log, if required by the director; and
(e) Any other test required by the director.
(B) Whole
cores or sidewall cores of the confining and injection zones and formation
fluid samples from the injection zone shall be taken. The director may accept
cores from nearby wells if the owner or operator can demonstrate that core
retrieval is not possible and that such cores are representative of conditions
at the well. The director may require the owner or operator to core other
formations in the bore hole.
(C)
The fluid temperature, pH, conductivity, pressure and the static fluid level of
the injection zone must be recorded.
(D) At a minimum, the owner or operator of a
Class I hazardous waste injection well shall submit for review by the director
determinations or calculations of the following for the injection and confining
zones:
(1) Fracture pressure; and
(2) Other physical and chemical
characteristics of the injection and confining zones; and
(3) Physical and chemical characteristics of
the formation fluids in the injection zone.
(E) Upon completion, but prior to operation,
the owner or operator shall conduct the following tests to verify hydrogeologic
characteristics of the injection zone:
(1) A
pump test; or
(2) Injectivity
tests.
(F) The director
reserves the right to witness all logging and testing required by this rule.
The owner or operator shall submit a schedule of such activities to the
director thirty days prior to conducting the initial test.
Notes
Rule promulgated under: RC Chapter 119.
Rule amplifies: RC 6111.043
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.