Ohio Admin. Code 3745-67-53 - Containment
If leachate or run-off from a pile is a hazardous waste, then either:
(A)
(1) The pile shall be placed on an
impermeable base that is compatible with the waste under the conditions of
treatment or storage;
(2) The owner
or operator must design, construct, operate, and maintain a run-on control
system capable of preventing flow onto the active portion of the pile during
peak discharge from at least a twenty-five-year storm;
(3) The owner or operator must design,
construct, operate, and maintain a run-off management system to collect and
control at least the water volume resulting from a twenty-four-hour,
twenty-five-year storm; and
(4)
Collection and holding facilities (e.g., tanks or basins) associated with
run-on and run-off control systems must be emptied or otherwise managed
expeditiously to maintain design capacity of the system; or
(B)
(1) The pile shall be protected from
precipitation and run-on by some other means; and
(2) No liquids or wastes containing free
liquids may be placed in the pile.
Notes
Rule promulgated under: RC Chapter 119.
Rule amplifies: RC 3734.12
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.