Ohio Admin. Code 4123:1-3-15 - [Effective 6/30/2025] Explosives and blasting
(A) Reserved.
(B) Definitions.
(1) "Approved storage facility" means a
facility for the storage of explosive materials covered by a license or permit
issued under authority of the appropriate federal agency.
(2) "Blast area" means the area in which
explosives loading and blasting operations are being conducted.
(3) "Blaster" means the person having a
comprehensive knowledge of the installation and use of appliances associated
with the type of blasting operations being performed, designated by the
employer to perform and direct the functions of placing and fixing explosives,
firing explosives, approaching misfires
of explosives, thawing explosives, and all other duties in connection with the blasting
operation.
(4) "Blasting agent"
means any material or mixture consisting of a fuel and an oxidizer used for blasting, but not classified an
explosive, and, in which none of the ingredients is classified as
an explosive provided the furnished (
mixed) product cannot be detonated with a
no.
number 8
test blasting cap.
(5) "Blasting
cap" means a metallic tube closed at one end, containing a charge of one or
more detonating compounds, and designed for, and
capable of, detonation from the sparks or flame
from a safety fuse inserted and crimped into the open end.
(6) "Bus wire" means an insulated expendable
wire used between connecting wires and leading wires.
(7) "Connecting wire" means an insulated
expendable wire used between electric blasting caps and the bus wires or
leading wires.
(8) "Detonating
cord" means a flexible cord containing a center core of high explosives
which, when detonated, will have sufficient
strength to detonate other cap-sensitive explosives with which
it
the detonating
cord is in contact.
(9)
"Detonator" means igniters, blasting caps, electric blasting caps, or similar
devices used to explode explosives.
(10) "Explosive" means any chemical compound
or mixture that is intended for the purpose of producing an explosion; that
. An explosive
contains any oxidizing and combustible units, or other ingredients in such
proportions, quantities, or packing that an ignition by fire, by friction, by
concussion, by percussion, or by a detonator, of any part of the compound
mixture may cause such a sudden generation of highly heated gases that the
resultant gaseous pressures are capable of producing destructive effects on
contiguous objects, or of destroying life or limb.
(11) "Fuse lighters" means special devices
for the purpose of igniting safety fuse.
(12) "Leading wire" means an insulated wire
used between the electric power source and the electric blasting cap
circuit.
(13) "Magazine" means any
building or other structure used for the storage of explosives.
(14) "Primed cartridge" means a cartridge of
explosives to which a detonator has been attached as a means of firing, and intended to be placed in the bore hole or
other explosive chamber for the purpose of exploding the remainder of the
charge.
(15) "Safety fuse" means
the slow-burning
slow burning commercially used blasting fuse, usually
consisting of a core of powder overspun with yarns and tapes,
and which may be treated with a
waterproofing compound, and intended to convey fire to the blasting caps or
explosive mass while minimizing the danger to the employee lighting
it.
(C) Specific
requirements for all blasting operations.
(1)
The employer shall designate one employee qualified as a blaster, to be in charge of blasting at each location
where blasting operations are being performed.
(2) The use of black powder is
prohibited.
(3) No explosives or
blasting agents shall be abandoned.
(4) Smoking, firearms, matches, open flame
lamps, and other fire, flame, heat, or
spark-producing devices are prohibited in or near explosive magazines or while
explosives are being handled, transported, or
used.
(5) When blasting is done
employees shall be removed from the area, or the
blast shall be covered, before firing, with a mat or mats so constructed as to
control the throw of fragments.
(6)
The blaster shall be responsible for using every reasonable precaution, such as visual and audible warning signals, flags,
and barricades, to ensure employee safety.
(7) Blasting operations in the proximity of
overhead power lines, communication lines, utility services,
or other services,
and
or structures shall not be carried on until the
operators or owners have been notified, and
measures have been taken to ensure the safety of the employer's
employees.
(8) Due precautions
shall be taken to prevent accidental discharge of electric blasting caps by
current induced by radar, radio transmitters, lightning, adjacent power lines,
dust storms, or other sources of extraneous electricity. These precautions
shall include:
(a) The suspension of all
blasting operations and removal of employees from the blasting area during the
approach and progress of an electrical storm.
(b) The posting of signs warning against the
use of mobile radio transmitters on all roads within one thousand feet
(304.8 meters) of the blasting
operations.
(9) Empty
boxes, paper, and fiber packing materials which
have previously contained high explosives shall not be used again for any
purpose, but shall be destroyed by burning
at a location approved by the blaster, and no employee shall be permitted
closer than one hundred feet (30.5 meters) after
the burning has started.
(10)
Containers of explosive materials shall not be opened within fifty feet
(15.2 meters) of any magazine. In opening cases,
nonsparking
non
sparking tools shall be used, except that metal slitters may be used for
opening fiberboard boxes.
(11)
Explosive materials that are obviously deteriorated or damaged shall not be
used and shall be destroyed by, or under the
direction of, the blaster.
(12) Flagmen posted on highways to stop
traffic during blasting operations shall be stationed far enough away from the
blasting for their own safety.
(D) Transportation of explosives.
(1) Surface transportation of explosives.
Any vehicle used to transport explosives on the job site shall
have a nonsparking
non sparking floor and side members and shall contain
a suitable fire extinguisher. Explosives and blasting caps shall not be
transported in the same vehicle.
(2) Underground transportation of explosives.
(a) No employee shall ride in any shaft
conveyance transporting explosives and blasting agents.
(b) Detonators and other explosives shall not
be transported at the same time in any shaft conveyance.
(c) Explosives or blasting agents, not in
original containers, shall be placed in a suitable container when transported
manually.
(d) Detonators, primers,
and other explosives shall be carried in separate containers when transported
manually.
(e) When detonators or
explosives are brought into an air lock, no employee except the blaster, lock
tender, and the employees necessary for carrying,
shall be permitted to enter the air lock. No other material, supplies, or
equipment shall be locked through with the explosives.
(f) Detonators and explosives shall be taken
separately into pressure working chambers.
(g) The blaster shall be responsible for the
receipt, unloading, storage, and on-site transportation of explosives and
detonators.
(E) Storage of explosives and blasting
agents.
(1) Blasting caps, electric blasting
caps, or other detonating devices shall not be stored in the same magazine with
other explosives or blasting agents.
(2) Primed cartridges shall not be
stored.
(3) All explosives stored
on the job site shall be stored in approved storage facilities. All brush and
combustible materials shall be kept clear of the magazine to a distance of
twenty-five feet 7.6 meters).
(4) Detonators and explosives shall not be
stored or kept in tunnels, shafts, or caissons. Detonators and explosives for
each round shall be taken directly from the magazines to the blasting zone and
immediately loaded. Detonators and explosives left over after loading a round
shall be removed from the working chamber before the connecting wires are
connected.
(F) Loading
of explosives or blasting agents.
(1) All
drill holes shall be sufficiently large to admit freely the insertion of the
packages of explosive materials.
(2) Tamping shall be done only with
nonsparking
non
sparking tools without exposed metal parts, except that
nonsparking
non
sparking metal connectors may be used for jointed poles. Violent tamping
is prohibited. Primed cartridges shall not be tamped.
(3) No holes shall be loaded except those to
be fired in the next round of blasting. After loading, all remaining explosives
shall be immediately returned to the magazine or removed from the area to a
distance of no less than one hundred feet (30.5
meters).
(4) Drilling shall
not be started until all remaining butts of old holes are examined for
unexploded charges, and if any are found, they
the unexploded
cartridges shall be disposed of before work proceeds.
(5) No person shall be allowed to deepen
drill holes which have contained explosives or blasting agents.
(6) No loaded holes shall be left unattended
or unprotected.
(7) The explosives
used in wet holes or holes, that may become
wet, shall be water-resistant.
(G) Initiation of explosive
charges.
(1) General.
(a) When a
safety fuse is used, the blasting cap shall be securely attached to
it
the safety
fuse with a standard ring type cap crimper. All primers shall be
assembled no less than fifty feet (15.2 meters)
from any magazine.
(b) Primers for
use in blasting shall be made up only as required for each round of
blasting.
(c) No blasting cap shall
be inserted in the explosive materials without first making a hole in the
cartridge for the cap with a nonsparking
non
sparking punch.
(d) If there
are any misfires while using cap and fuse, all employees shall be required to
remain away from the charge for at least an hour. If electric blasting caps are
used and a misfire occurs, this waiting period may be reduced to thirty
minutes.
(2) Electric
blasting caps.
(a) Bus wires, connecting
wires, and lead wires shall be insulated single
solid wires of sufficient current-carrying capacity.
(b) Blasters, when testing circuits to
charged holes, shall use only blasting galvanometers or other instruments that
are specifically designed for the purpose.
(c) Only the employee making the final check
on the wire connections shall fire the shot. All connections shall be made from
bore hole back to the source of firing current, and the leading wires shall
remain shorted, and not
be connected to the blasting machine or
other source of current, until the charge is to
be fired.
(d) In any single blast
using electric blasting caps, all caps shall be of the same style,
or function,
and of the same manufacture.
(e) Electric blasting shall be carried out by
using blasting circuits or power circuits in accordance with the electric
blasting cap manufacturer's recommendations, or the recommendations
of an approved contractor or his
their designated representative.
(f) When firing a circuit of electric
blasting caps, every reasonable precaution shall be exercised to ensure that an
adequate quantity of delivered current is available, in accordance with the
manufacturer's recommendations.
(3) Use of safety fuse.
(a) No one shall be permitted to carry
detonators or primers of any kind on the person.
(b) The minimum length of safety fuse to be
used in blasting shall be as required by applicable state law, but shall be no less than thirty inches
(76.2 centimeters).
(c) At least two employees shall be present
when multiple cap and fuse blasting is done by hand lighting methods.
(d) No more than twelve fuses may be lighted
by any individual when hand lighting devices are used, provided that when two
or more safety fuses in a group are lighted as one by means of igniter cord, or
other similar fuse-lighting devices, they
the safety fuses
may be considered as one fuse.
(e)
The so-called "drop fuse" method of
dropping or pushing a primer, or any
explosive, with a lighted fuse attached is
prohibited.
(4) Use of
detonating cord.
(a) Care shall be taken to
select a detonating cord consistent with the type and physical condition of the
bore hole and stemming and type of explosives used.
(b) Detonating cord shall be handled and used
with the same precaution as with other explosives.
(c) The line of detonating cord extending out
of a bore hole, or from a charge, shall be cut from a
supply spool before loading the remainder of the bore hole or placing
additional charges.
(d) Detonating
cord shall be handled and used with care to avoid damaging or severing the cord
during and
loading, after loading,
and hooking-up.
(e) Detonating cord
connections shall be made in accordance with approved methods. Knot-type or
other cord-to-cord connections shall be made only with detonating cord in which
the explosive core is dry.
(f) All
detonating cord trunklines and branchlines shall be free of loops, sharp kinks,
or angles that direct the cord back toward the oncoming line of
detonation.
(g) All detonating cord
connections shall be inspected before firing the blast.
(h) When detonating cord millisecond-delay
connectors or short-interval-delay electric blasting caps are used with
detonating cord, the practice shall conform strictly to the manufacturer's
recommendations.
(i) When
connecting a blasting cap or an electric blasting cap to detonating cord, the
blasting cap shall be taped or otherwise attached
securely along the side or the end of the detonating cord, with the end of the
blasting cap containing the explosive charge
pointed in the direction in which the detonation is to proceed.
(j) Detonators for firing the trunkline shall
not be brought to the loading area, nor attached
to the detonating cord, until everything else is
in readiness for the blast.
(H) Underwater blasting.
(1) Loading tubes and casings of dissimilar
metals shall not be used in electric blasting because of possible electric
transient currents from galvanic action of the metals and water.
(2) In marine blasting only water-resistant
blasting caps and detonating cords shall be used. When a loading tube is
necessary one of
, a nonsparking
non
sparking
type
loading tube shall be used.
(3) No blast shall be fired while any vessel
under way is closer than one thousand five hundred feet (457.2 meters) to the blasting area. Those on board
vessels or craft moored or anchored within one thousand five hundred feet
(457.2 meters) shall be notified before a blast
is fired.
(4) If swimming or diving
operations are in progress in the vicinity of the blasting area, signals and
arrangements shall be agreed upon to assure that no blast shall be fired while
any employee is in the water.
(5)
Blasting flags shall be displayed.
(6) When more than one charge is placed under
water, a float device shall be attached to an element of each charge in such
manner that it
the
float device will be released by the firing. Misfires shall be handled in
accordance with the requirements of paragraph (G)(1)(d) of this rule.
Notes
Promulgated Under: 119.03
Statutory Authority: 4121.12, 4121.121, 4121.13, Const. Art. II, Sec. 35
Rule Amplifies: 4121.47
Prior Effective Dates: 04/01/1968, 11/01/1979, 01/01/2011
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.