Ohio Admin. Code 4123:1-5-25 - Vehicle-mounted elevating and rotating work platforms
The employer shall
will provide a vehicle that will assure a stable
support for the aerial device.
Each aerial device when mounted on a vehicle and used in a
specific configuration, shall
will be capable of sustaining a static load one and
one-half times its rated capacity when the vehicle is on a firm and level
surface.
Each aerial device, when mounted on a vehicle and used in a
specific configuration, shall
will comprise a unit capable of sustaining a static
load one and one-third times the rated capacity for that specific configuration
in every position in which the load can be placed within the definition of the
specific configuration, when the vehicle is on a slope of five degrees downward
in the direction most likely to cause overturning. If having the outriggers
extended to a firm footing is a part of the definition of the configuration,
then outriggers shall
will be extended to provide maximum leveling for the
purpose of determining whether the unit meets the stability
requirements
specifications. If other facilities, such as means of
turntable leveling are provided to minimize the effect of sloping terrain, then
those facilities shall
will be utilized for the purpose of determining
whether the unit meets the stability requirement
specification.
Operating instruction plates shall
will be provided
and attached to all aerial devices. The plate or plates
shall
will be
located in a readily accessible area, shall be clearly visible, and
shall
will
state the following: make, model and manufacturer's serial number; rated
capacity; platform height, manufacturer's recommended operating pressure of
pneumatic and hydraulic systems; caution and restrictions of operation;
operating instructions and manufacturer's rated line voltage. Alternative
configurations (see paragraph (A)(1) of this rule) shall require
will
need in addition to the above: chart, schematic or scale showing
capacities of all combinations in their operating position, and caution and
restrictions of operation of all alternate or combinations of alternate
configurations.
Platform height shall
will be measured at its maximum elevation from the
floor of the platform to the ground.
The load, in calculating the capacity rating,
shall
will be
the platform load and supplemental loads which may be affixed directly to the
boom. The capacity rating shall
will be designated with boom or booms extended to the
maximum horizontal reach attainable throughout full rotation of its pedestal.
Capacities of the equipment in other positions must
will be specified
separately.
Reach shall
will be measured
from the center line of pedestal (rotation) to outer edge (rail) of the
platform.
The operating instruction plate(s) shall state whether the
aerial device is insulated or noninsulated. A label (minimum one-fourth-inch
letters) shall
will be placed at each operating control
station.
In the case of insulated units, the operating instruction
plate(s) shall
will clearly state the rate line voltage for which the
aerial device is designed.
The basic structural elements of the aerial device which
support the platform shall
will be designed such that the yield point of the
materials used for any such elements shall
will not be
exceeded with three times the rated load(s) on the aerial device. The same
structural factor of safety shall
will apply to the platform.
Articulating boom and extensible platforms, specifically
designed as personnel carriers, shall
will have both platform (upper) and lower controls.
Upper controls shall
will be in or beside the platform within easy reach of
the operator. Lower controls shall
will provide for overriding the upper controls. All
controls shall
will be guarded or shall
will be of such
type that they cannot be accidentally actuated. They shall
will be plainly
marked as to their function.
Where the elevation of the boom or operation of the outriggers
is accomplished by means of a hydraulic cylinder assembly, a pneumatic system
or an electrically operated system, pilot operated check valves or other
appropriate "fail safe" devices shall
will be provided to prevent free fall of the boom or
collapse of the outriggers in the event of power failure.
Each platform shall
will be provided with a guardrail no more than
forty-five inches and no less than thirty-nine inches above the floor of the
platform, an intermediate rail, and a toeboard, or its equivalent, around the
periphery.
All critical components of hydraulic or pneumatic systems
shall
will
withstand a pressure of no less than four times the normal operating pressure
of the system. Critical components are those in which a failure would result in
a free fall or free rotation of the boom. All noncritical components
shall
will
have a bursting safety factor of two.
Test electrodes shall
will be permanently located on the inside and outside
surfaces of the insulated portion of the boom. Insulated units under sixty-nine
kilovolts do not require
need permanent test electrodes. These electrodes
shall
will be
two to six inches from the metal portion of the lower end of the insulated
upper boom. All hydraulic and air lines bridging the insulated portion of the
boom shall
will have metallic couplings adjacent to the test
electrodes. Couplings shall
will be
insulated from the metal portion of the boom and electrically connected to the
test electrodes.
Employees of the electric utility and telecommunications
industries and their contractors and subcontractors shall
will not be
required to transfer from an aerial basket to any object or structure, or from
any object or structure to an aerial basket, while the aerial basket is
elevated above the ground. This does not apply to operations where the aerial
basket is extended over a flat surface and where the hazard of falling has been
eliminated.
Vehicles upon which elevating or rotating work platform are
mounted shall
will be provided with flasher lights.