Ohio Admin. Code 4123:1-5-99 - Table of standard materials and dimensions

Where required specified by Chapter 4123:1-5 of the Administrative Code, the following table to this rule shall will be used.

Table of standard materials and dimensions*

Material

Distance of opening from hazard zone

Maximum width of opening allowable

Minimum gauge (U.S. Standard) or thickness

Minimum height of guard from floor or platform level

Inches

Inches

Feet

Woven wire

Under 4

*see table below

No. 16

7

4-15

No. 12

7

Expanded metal

Under 4

* see table below

No. 18

7

No. 13

Perforated metal

Under 4

* see table below

No. 20

7

4-15

No. 14

7

Sheet metal

Under 4

* see table below

No. 22

7

4-15

No. 22

7

Wood or metal strip not crossed

Under 4

* see table below

Wood 3/4 Metal No. 16

4-15

Wood 3/4 Metal No. 16

7

Standard guard railing*

Minimum 15

-

-

-

Maximum 20

Distance of opening from hazard zone (inches)

0.5 to 1.5

0.25

Over 1.5 to 2.5

0.375

Over 2.5 to 3.5

0.5

Over 3.5 to 5.5

0.625

Over 5.5 to 6.5

0.75

Over 6.5 to 7.5

0.875

Over 7.5 to 12.5

1.25

Over 12.5 to 15.5

1.5

Over 15.5 to 17.5

1.875

Over 17.5 to 31.5

2.125

Notes

Ohio Admin. Code 4123:1-5-99
Effective: 9/1/2023
Five Year Review (FYR) Dates: 11/1/2026
Promulgated Under: 119.03
Statutory Authority: 4121.12, 4121.121, 4121.13
Rule Amplifies: 4121.47
Prior Effective Dates: 01/01/1986, 04/10/2011, 06/01/2016