Ohio Admin. Code 4731-17-04 - Disinfection and sterilization
Instruments and other equipment classified by the FDA as
reusable, used by licensees who perform or participate in invasive procedures
shall be appropriately disinfected and sterilized according to acceptable and
prevailing standards for disinfection and sterlization
sterilization which shall include at least the
following:
(A) Instruments and devices
that enter the patient's vascular system or other normally sterile areas of the
body shall be sterilized before being used for each patient;
(B) Instruments and devices that touch intact
mucous membranes but do not penetrate the patient's body surfaces shall be
sterilized when possible, or undergo high-level disinfection if they cannot be
sterilized before using for each patient;
(C) Instruments and devices that are able to
withstand repeated exposure to heat shall be heat sterilized. Sterilization
shall be accomplished by autoclave, dry heat, unsaturated chemical vapor,
ethylene oxide, hydrogen peroxide gas plasma, or any other FDA/ EPA-approved
method;
(D) Instruments and items
that cannot withstand heat sterilization shall be subjected to a high level
disinfection process, including compliance with any manufacturer's instructions
for disinfection;
(E) Heat
sterilizing devices shall be tested for proper function on a weekly basis by
means of a biological monitoring system that indicates microorganism kill.
Documentation shall be maintained either in the form of a log reflecting dates
and person(s) conducting the testing or copies of reports from an independent
testing entity. The documentation shall be maintained for a period of at least
two years. In the event of a positive biological spore test, the licensee must
take immediate remedial action to ensure that heat sterilization is being
accomplished;
(F) Surface
disinfection:
(1) Environmental surfaces that
are contaminated by blood or other body fluids shall be disinfected with a
chemical germicide that is registered with the environmental protection agency
as a "hospital disinfectant" or sodium hypochlorite and is mycobactericidal at
use-dilution. The disinfection process shall be followed before each patient;
and
(2) Impervious backed paper,
aluminium
aluminum foil or plastic wrap shall be used to cover
surfaces that may be contaminated by blood or other body fluids and that are
difficult or impossible to disinfect. The cover shall be removed, discarded and
then replaced between patients.
(G) Single use items used in treating a
patient, which have become contaminated by blood or other body fluids, shall be
discarded and not reused, unless sterilized and reused in accordance with
current guidelines established by the FDA. Single use items being reused in
treating a patient shall be adequately cleaned and sterilized. Single use items
shall not be reused if the items' physical characteristics and quality have
been adversely affected or if the items are incapable of being reused safely
and effectively for their intended use.