Okla. Admin. Code § 252:515-7-3 - Compliance with OWRB rules

All monitoring wells, borings, and/or piezometers shall be constructed and/or plugged in accordance with the applicable requirements of the OWRB at OAC 785:35.

(1) Flush mounting prohibited. Flush-mounting of monitoring wells and piezometers is prohibited.
(2) Multi-zone completions prohibited. Multi-zone completions of monitoring wells and piezometers are prohibited.
(3) Notch. The well casing of monitoring wells shall be notched to mark the point of measurement for groundwater elevation.
(4) Latitude, longitude, surface elevation. Latitude, longitude, and surface elevation, measured by a licensed surveyor, shall be permanently marked on the protective casing of each monitoring well.

Notes

Okla. Admin. Code § 252:515-7-3
Added at 20 Ok Reg 1151, eff 6-1-03

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.