Or. Admin. R. 333-116-0840 - Safety Considerations and Quality Management for PET Facilities
(1) The licensee
must establish and implement a Quality Management program pursuant to OAR
333-116-0125 for PET products, as well as other production and calibration
products.
(2) PET instrumentation
and other equipment unique to the PET process must meet all applicable
radiation protection standards pursuant to division 120 of these
rules.
(3) Area monitors must be
visible and audible to accelerator operators. Monitors must be checked for
proper operation daily.
(4) Wasted
targets must be treated as radioactive waste and must be properly dismantled,
shielded, stored, and disposed.
(5)
Accelerator shielding design and safety must meet requirements of OAR
333-109-0025.
(6) Shielding around
guide-bends, targets, hot-cells, purification manifolds, etc. must ensure that
limits in OAR 333-120-0180 and 333-120-0190 have been met in all areas of beam
and nuclide production.
(7)
Security provisions for unauthorized access, janitorial services, maintenance,
visitors, tours, and personnel-in-training must conform to requirements in OAR
333-120-0180, 333-120-0250 and 333-120-0260.
Notes
Statutory/Other Authority: ORS 453.635
Statutes/Other Implemented: ORS 453.605 - 453.807