(1) Spa pool recirculation piping shall be sized to carry the following maximum design flows:
(a) Discharge piping (except copper) -- 10 ft./sec. (3.05 m/sec.);
(b) Discharge piping (copper) -- 8 ft./sec. (2.44 m/sec.);
(c) Suction velocity -- 6 ft./sec. (1.83m/sec.).
(2) Pool recirculation piping, if plastic, shall comply with National Sanitation Foundation Standard Number 14 for Plastic Piping System Components and Related Materials.
(3) Spa pool backwash and/or drain lines shall be permanently piped with an air break. For all spa pools built after May 1, 1986, the pool backwash and/or drain line shall be permanently piped with an air break to discharge into an approved sewerage system.