Or. Admin. Code § 340-050-0070 - Criteria for Site Selection and Approval
(1) Normally, tillable agricultural land is
suitable for the land application of biosolids and domestic septage.
(2) To be considered for biosolids or
domestic septage land application, sites should meet all the following
conditions:
(a) Sites should be on a stable
geologic formation not subject to flooding or excessive runoff from adjacent
land. If periodic flooding cannot be avoided, the period of application should
be restricted and soil incorporation is recommended.
(b) At the time when liquid biosolids or
domestic septage are applied, the minimum depth to permanent groundwater should
be four feet and the minimum depth to temporary groundwater should be one foot.
Sites approved for year-round application should be evaluated carefully to
ensure that groundwater separation distances conform with these
requirements.
(c) Topography of the
site should be suitable to allow normal agricultural operations. Where needed,
runoff and erosion control measures should be constructed. In general, liquid
biosolids or domestic septage should not be surface applied on bare soils where
the ground slope exceeds 12 percent. Well vegetated sites with slopes up to 30
percent may be used for dewatered or dried biosolids, or for liquid biosolids
or domestc septage application with appropriate management to prevent
runoff.
(d) Soil should have a
minimum rooting depth of 24 inches. The underlying substratum to at least 24
inches should not be rapidly draining so that leachate will not be short
circuited to groundwater.
(e) Sites
with saline and/or sodic soils should be avoided.
(3) Discretion should be used in approving
application of biosolids or domestic septage on land that is in close proximity
to residential areas.
(a) A buffer strip
large enough to prevent nuisance odors or wind drift is needed. Size of the
buffer strip will be determined by the Department on a case-by-case basis and
depend upon the method of application used, total solids content, and proximity
to sensitive areas, for example:
(A) Direct
injection: no limit required;
(B)
Truck spreading (liquid): 0 to 200 feet;
(C) Spray irrigation: 50 to 500
feet;
(D) Cake or dried solids: 0
to 50 feet.
(b) Buffer
strips should be provided along well traveled highways. The size of the buffer
strip will vary with local conditions and should be left to the discretion of
the Department field representative.
(c) No bulk Class B biosolids or domestic
septage should be spread at the site closer than 50 feet to any ditch, channel,
pond or waterway or within 200 feet of a domestic water source or
well.
Notes
Stat. Auth.:ORS 468
Stats. Implemented:ORS 468B.095