Or. Admin. Code § 340-071-0285 - Redundant Systems
(1) Criteria for
approval. Construction permits may be issued for redundant absorption field
systems to serve single family dwellings on sites that meet both of the
following conditions.
(a) The lot or parcel
was created before January 1, 1974.
(b) The lot or parcel size will not
accommodate a standard system.
(2) Design criteria:
(a) Each redundant absorption system must
contain two complete absorption fields.
(b) Each absorption field must be large
enough to accommodate the projected daily sewage flow from the
dwelling.
(c) A minimum separation
of 10 feet (12 feet center to center) must be maintained between absorption
trenches designed to operate simultaneously, and a minimum separation of 4 feet
(6 feet center to center) must be maintained between adjacent absorption
trenches.
(d) The system must be
designed to alternate between the absorption fields with the use of a diversion
valve or other method approved by the agent.