Or. Admin. Code § 340-073-0050 - Distribution Boxes, Drop Boxes, and Diversion Valves: Dosing Tanks
(1) Dosing tanks
must meet the standards described in OAR
340-073-0025, except as
otherwise allowed in this rule.
(2)
Each dosing tank employing one or more pumps must have a minimum liquid
capacity equal to the projected daily sewage flow for flows up to 1,200 gallons
per day. The department will determine tank sizing for dosing tanks with
projected daily sewage flows greater than 1,200 gallons per day. The liquid
capacity of dosing tanks must be as measured from the invert elevation of the
inlet fitting.
(3) Each dosing tank
must be provided with a service access manhole having a minimum horizontal
measurement of 18 inches.
(4) Each
dosing tank proposed to serve a commercial facility containing more than one
pump or siphon must be provided with at least one service access manhole that
provides adequate space to construct, install, service, and operate the
equipment in accordance with the requirements of OAR 340, divisions 071 and
073.
(5) The installation manual
described in OAR 340-073-0025(13)
must include additional information about siphon selection, installation of the
pump or siphon screen, pump control and alarm levels, and the watertight
pass-through methods for electric wiring and pipe.
(6) Dosing tanks with siphons must be
designed and sized for each specific project. The tank manufacturer must
specify the type or model of siphon, screen, and related apparatus that are
compatible with each dosing tank.
(7) The inlet fitting must extend below the
lowest operating level of the pump or siphon.