Or. Admin. Code § 340-202-0210 - Prevention of Significant Deterioration Increments: Ambient Air PSD Increments
(1) This
rule defines significant deterioration. In areas designated as Class I, II or
III, emissions from new or modified sources must be limited such that aggregate
increases in regulated pollutant concentration over the baseline concentration,
as defined in OAR 340-225-0020, are less than the
following PSD increments or maximum allowable increases:
(a) For Class I areas:
(A) PM2.5:
(i) Annual arithmetic mean = 1 microgram per
cubic meter.
(ii) 24-hour maximum =
2 micrograms per cubic meter.
(B) PM10:
(i) Annual arithmetic mean = 4 micrograms per
cubic meter
(ii) 24-hour maximum =
8 micrograms per cubic meter.
(C) Sulfur dioxide:
(i) Annual arithmetic mean = 2 micrograms per
cubic meter.
(ii) 24-hour maximum =
5 micrograms per cubic meter.
(iii)
3-hour maximum = 25 micrograms per cubic meter.
(D) Nitrogen dioxide: Annual arithmetic mean
= 2.5 micrograms per cubic meter.
(b) For Class II areas:
(A) PM2.5:
(i) Annual arithmetic mean = 4 micrograms per
cubic meter.
(ii) 24-hour maximum =
9 micrograms per cubic meter.
(B) PM10:
(i) Annual arithmetic mean = 17 micrograms
per cubic meter.
(ii) 24-hour
maximum = 30 micrograms per cubic meter.
(C) Sulfur dioxide:
(i) Annual arithmetic mean = 20 micrograms
per cubic meter.
(ii) 24-hour
maximum = 91 micrograms per cubic meter.
(iii) 3-hour maximum = 512 micrograms per
cubic meter.
(D)
Nitrogen dioxide: Annual arithmetic mean = 25 micrograms per cubic
meter.
(c) For Class III
areas:
(A) PM2.5:
(i) Annual arithmetic mean = 8 micrograms per
cubic meter.
(ii) 24-hour maximum =
18 micrograms per cubic meter.
(B) PM10:
(i) Annual arithmetic mean = 34 micrograms
per cubic meter.
(ii) 24-hour
maximum = 60 micrograms per cubic meter.
(C) Sulfur dioxide:
(i) Annual arithmetic mean = 40 micrograms
per cubic meter.
(ii) 24-hour
maximum = 182 micrograms per cubic meter.
(iii) 3-hour maximum= 700 micrograms per
cubic meter.
(D)
Nitrogen dioxide: Annual arithmetic mean = 50 micrograms per cubic
meter.
(2)
For any period other than an annual period, the applicable maximum allowable
increase or PSD increment may be exceeded during one such period per year at
any one location.
NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040.
Notes
To view tables referenced in rule text, click here to view rule.
Statutory/Other Authority: ORS 468.020 & 468A
Statutes/Other Implemented: ORS 468A.025 & 468A.035
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.