Or. Admin. Code § 340-226-0210 - Grain Loading Standards: Particulate Emission Limitations for Sources Other Than Fuel Burning Equipment, Refuse Burning Equipment and Fugitive Emissions
(1) This rule does
not apply to fugitive emissions sources, fuel burning equipment, refuse burning
equipment, or to solid fuel burning devices certified under OAR
340-262-0500.
(2) No person may cause, suffer, allow, or
permit particulate matter emissions from any air contaminant source in excess
of the following limits:
(a) For sources
installed, constructed, or modified before June 1, 1970:
(A) 0.10 grains per dry standard cubic foot
provided that all representative compliance source test results collected prior
to April 16, 2015, demonstrate emissions no greater than 0.080 grains per dry
standard cubic foot;
(B) If any
representative compliance source test results collected prior to April 16, 2015
demonstrate emissions greater than 0.080 grains per dry standard cubic foot, or
if there are no representative compliance source test results, then:
(i) 0.24 grains per dry standard cubic foot
prior to Dec. 31, 2019; and
(ii)
0.15 grains per dry standard cubic foot on or after Jan. 1, 2020; and
(C) In addition to the limits in
paragraphs (A) or (B), for equipment or a mode of operation that is used less
than 876 hours per calendar year, 0.24 grains per dry standard cubic foot from
April 16, 2015 through December 31, 2019, and 0.20 grains per dry standard
cubic foot on or after Jan. 1, 2020.
(b) For sources installed, constructed, or
modified on or after June 1, 1970 but prior to April 16, 2015:
(A) 0.10 grains per dry standard cubic foot
provided that all representative compliance source test results prior to April
16, 2015 demonstrate emissions no greater than 0.080 grains per dry standard
cubic foot; or;
(B) If any
representative compliance source test results prior to April 16, 2015 are
greater than 0.080 grains per dry standard cubic foot, or if there are no
representative compliance source test results, then 0.14 grains per dry
standard cubic foot.
(c)
For sources installed, constructed or modified after April 16, 2015, 0.10
grains per dry standard cubic foot.
(d) The owner or operator of a source
installed, constructed, or modified before June 1, 1970 who is unable to comply
with the standard in subparagraph (a)(B)(ii) may request that DEQ grant an
extension allowing the source up to one additional year to comply with the
standard. The request for an extension must be submitted no later than Oct. 1,
2019.
(3) Compliance with
the emissions standards in section (2) is determined using:
(a) Oregon Method 5;
(b) DEQ Method 8, as approved by DEQ for
sources with exhaust gases at or near ambient conditions;
(c) DEQ Method 7 for direct heat transfer
sources [NOTE: DEQ Methods are described in the DEQ Source Sampling Manual
published with OAR 340-200-0035] ; or
(d) An alternative method approved by
DEQ.
(e) For purposes of this rule,
representative compliance source test results are data that was obtained:
(A) No more than ten years before April 16,
2015; and
(B) When a source is
operating and maintaining air pollution control devices and emission reduction
processes at the highest reasonable efficiency and effectiveness to minimize
emissions based on the current configuration of the emissions unit and
pollution control equipment.
NOTE: This rule is included in the State of Oregon Clean Air Act Implementation Plan that EQC adopted under OAR 340-200-0040
Notes
Statutory/Other Authority: ORS 468.020, 468A.025 & 468A.070
Statutes/Other Implemented: ORS 468A.025 & 468A.070
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.