Or. Admin. Code § 340-230-0387 - Other Monitoring Requirements
(1) Operating parameters. The owner or
operator must monitor the following operating parameters:
(a) Load level of each municipal waste
combustion unit.
(b) Temperature of
flue gases at the inlet of the particulate matter air pollution control
device.
(c) Carbon feed rate if
activated carbon is used to control dioxins/furans or mercury
emissions.
(2) Unit
load:
(a) If the municipal waste combustion
unit generates steam, the owner or operator must install, calibrate, maintain,
and operate a steam flowmeter or a feed water flowmeter and meet five
requirements:
(A) Continuously measure and
record the measurements of steam (or feed water) in kilograms (or pounds) per
hour.
(B) Calculate thesteam (or
feed water) flow in 4-hour block averages.
(C) Calculate the steam (or feed water) flow
rate using the method in "American Society of Mechanical Engineers Power Test
Codes: Test Code for Steam Generating Units, Power Test Code 4.1--1964
(R1991)," section 4.
(D) Design,
construct, install, calibrate, and use nozzles or orifices for flow rate
measurements, using the recommendations in "American Society of
Mechanical Engineers Interim Supplement 19.5 on Instruments and Apparatus:
Application, Part II of Fluid Meters," 6th Edition
(1971), chapter 4.
(E) Before each dioxins/furans stack test, or
at least once a year, calibrate all signal conversion elements associated with
steam (or feed water) flow measurements according to the manufacturer
instructions.
(b) If the
municipal waste combustion units do not generate steam, or, if the municipal
waste combustion units have shared steam systems and steam load cannot be
estimated per unit, the owner or operator must determine, to the Department's
satisfaction, one or more operating parameters that can be used to continuously
estimate load level (for example, the feed rate of municipal solid waste or
refuse-derived fuel). The owner or operator must continuously monitor the
selected parameters.
(3)
Pollution control device inlet temperature. The owner or operator must install,
calibrate, maintain, and operate a device to continuously measure the
temperature of the flue gas stream at the inlet of each particulate matter
control device.
(4) Carbon
injection rate. If the municipal waste combustion unit uses activated carbon to
control dioxins/furans or mercury emissions, the owner or operator must meet
three requirements:
(a) Select a carbon
injection system operating parameter that can be used to calculate carbon feed
rate (for example, screw feeder speed).
(b) During each dioxins/furans and mercury
stack test, determine the average carbon feed rate in kilograms (or pounds) per
hour. Also, determine the average operating parameter level that correlates to
the carbon feed rate. Establish a relationship between the operating parameter
and the carbon feed rate in order to calculate the carbon feed rate based on
the operating parameter level.
(c)
Continuously monitor the selected operating parameter during all periods when
the municipal waste combustion unit is operating and combusting waste and
calculate the 8-hour block average carbon feed rate in kilograms (or pounds)
per hour, based on the selected operating parameter. When calculating the
8-hour block average, the owner or operator must do two things: (1) Exclude
hours when the municipal waste combustion unit is not operating. (2) Include
hours when the municipal waste combustion unit is operating but the carbon feed
system is not working correctly.
(5) Minimum data. The owner or operator must
obtain the minimum data as prescribed in subsections (a)-(c) below:
(a) Where continuous parameter monitoring
systems are used, obtain 1-hour arithmetic averages for the following three
parameters:
(A) Load level of the municipal
waste combustion unit.
(B)
Temperature of the flue gases at the inlet of the particulate matter control
device; and
(C) Carbon feed rate if
activated carbon is used to control dioxins/furans or mercury
emissions.
(b) Obtain at
least two data points per hour in order to calculate a valid 1-hour arithmetic
average.
(c) Obtain valid 1-hour
averages for at least 75 percent of the operating hours per day for 90 percent
of the operating days per calendar quarter. An operating day is any day the
unit combusts any municipal solid waste or refuse-derived fuel.
(d) If the owner or operator does not obtain
the minimum data required in subsections (a) through (c), the owner or operator
is in violation of the data collection requirement and must notify the
Department according to OAR
340-230-0395(4)(b)(E)