The definitions in OAR
340-200-0020,
340-204-0010 and this rule apply
to this division. If the same term is defined in this rule and
340-200-0020 or
340-204-0010, the definition in
this rule applies to this division.
(1) "Baseline emissions rate" means a
source's actual emissions rate during the baseline period, as defined in OAR
340-200-0020, expressed as
pounds of emissions per thousand square feet of finished product, on a 1/8"
basis.
(2) "BLS" means black liquor
solids, dry weight.
(3) "Continuous
monitoring" means instrumental sampling of a gas stream on a continuous basis,
excluding periods of calibration.
(4) "Daily arithmetic average" means the
average concentration over the twenty-four hour period in a calendar day, as
determined by continuous monitoring equipment or reference method testing.
Determinations based on EPA reference methods using the DEQ Source Sampling
Manual consist of three separate consecutive runs having a minimum sampling
time of sixty minutes each and a maximum sampling time of eight hours each.
[NOTE: DEQ's Source Sampling Manual is published with OAR
340-200-0035; EPA Reference
Methods are found at Appendix A to 40 C.F.R. Part
60 .] The three values for
concentration (ppm or grains/dscf) are averaged and expressed as the daily
arithmetic average which is used to determine compliance with process weight
limitations, grain loading or volumetric concentration limitations and to
determine daily emission rate.
(5)
"Dry standard cubic meter" means the amount of gas that would occupy a volume
of one cubic meter, if the gas were free of uncombined water, at a temperature
of 20° C. (68° F.) and a pressure of 760 mm of mercury (29.92 inches of
mercury). The corresponding English unit is dry standard cubic foot.
(6) "Kraft mill" or "mill" means any
industrial operation which uses for a cooking liquor an alkaline sulfide
solution containing sodium hydroxide and sodium sulfide in its pulping
process.
(7) "Lime kiln" means any
production device in which calcium carbonate is thermally converted to calcium
oxide.
(8) "Non-condensables" mean
gases and vapors, contaminated with TRS compounds, from the digestion and
multiple-effect evaporation processes of a mill.
(9) "Operations" includes plant, mill, or
facility.
(10) "Other sources" as
used in OAR
340-234-0200 through
340-234-0270 means sources of
TRS emissions in a kraft mill other than recovery furnaces, lime kilns, smelt
dissolving tanks, sewers, drains, categorically insignificant activities and
wastewater treatment facilities including but not limited to:
(a) Vents from knotters, brown stock washing
systems, evaporators, blow tanks, blow heat accumulators, black liquor storage
tanks, black liquor oxidation system, pre-steaming vessels, tall oil recovery
operations; and
(b) Any vent which
is shown to contribute to an identified nuisance condition.
(11) "Production" as used in OAR
340-234-0200 through
340-234-0270 means the daily
amount of air-dried unbleached pulp, or equivalent, produced during the 24-hour
period each calendar day, or DEQ approved equivalent period, and expressed in
air-dried metric tons (admt) per day. The corresponding English unit is
air-dried tons (adt) per day;
(12)
"Recovery furnace" means the combustion device in which dissolved wood solids
are incinerated and pulping chemicals recovered from the molten smelt. For OAR
340-234-0200 through
340-234-0270, this term includes
a direct contact evaporator, if present.
(13) "Recovery system" means the process by
which all or part of the cooking chemicals may be recovered, and cooking liquor
regenerated from spent cooking liquor, including evaporation, combustion,
dissolving, fortification, and storage facilities associated with the recovery
cycle.
(14) "Smelt dissolving tank
vent" means the vent serving the vessel used to dissolve the molten smelt
produced by the recovery furnace.
(15) "Special problem area" means the
formally designated Portland, Eugene-Springfield, and Medford AQMAs and other
specifically defined areas that the EQC may formally designate in the future.
The purpose of such designation will be to assign more stringent emission
limits as may be necessary to attain and maintain ambient air standards or to
protect the public health or welfare.
(16) "Tempering oven" means any facility used
to bake hardboard following an oil treatment process.
(17) "Wigwam waste burner" means a burner
which consists of a single combustion chamber, has the general features of a
truncated cone, and is used for incineration of wastes.
[NOTE: This rule is included in the State of Oregon Clean Air
Act Implementation Plan that EQC adopted under OAR
340-200-0040.]
Notes
Or. Admin. Code
§
340-234-0010
[DEQ 37, f. 2-15-72, ef.
3-1-72; DEQ 4-1993, f. & cert. ef. 3-10-93 ]; [DEQ 50, f. 2-9-73, ef.
3-1-73; DEQ 137, f. & ef. 6-10-77; DEQ 2-1990, f. & cert. ef. 1-24-90;
DEQ 4-1993, f. & cert. ef. 3-10-93; DEQ 22-1995, f. & cert. ef. 10-6-95
]; [DEQ 2-1990, f. & cert. ef. 1-24-90; DEQ 4-1993, f. & cert. ef.
3-10-93; DEQ 22-1995, f. & cert. ef. 10-6-95 ]; [DEQ 26, f. 3-31-71, ef.
4-25-71; DEQ 132, f. & ef. 4-11-77; DEQ 7-1979, f. & ef. 4-20-79; DEQ
22-1991, f. & cert. ef. 11-13-91; DEQ 4-1993, f. & cert. ef. 3-10-93;
DEQ 4-1995, f. & cert. ef. 2-17-95 ]; [DEQ 32, f. 11-23-71, ef. 12-15-71;
DEQ 15-1980, f. & ef. 5-23-80; DEQ 4-1993, f. & cert. ef. 3-10-93 ];
[DEQ 37, f. 2-15-72, ef. 3-1-72; DEQ 4-1993, f. & cert. ef. 3-10-93 ]; DEQ
14-1999, f. & cert. ef. 10-14-99, Renumbered from 340-025-0005,
340-025-0150, 340-025-0220, 340-025-0305, 340-025-0350, 340-025-0410; DEQ
8-2007, f. & cert. ef. 11-8-07;
DEQ
7-2015, f. & cert. ef.
4/16/2015;
DEQ
13-2019, amend filed 05/16/2019, effective
5/16/2019;
DEQ
19-2022, amend filed 11/18/2022, effective
3/1/2023
Publications: Publications referenced are available from the
agency.
Statutory/Other Authority: ORS
468.020 &
468A.025
Statutes/Other Implemented: ORS